Measurement of pacing threshold.

H Ector, E Witters, L Tanghe

    Pacing and Clinical Electrophysiology : PACE
    |January 1, 1985
    PubMed
    Summary

    This study reports pacing thresholds for Cardiac Pacemakers, Inc. (CPI) 4118 tined leads, finding low constant current (≤0.6 mA) and constant voltage (≤0.5 V) thresholds in most cases. No definite difference was found between pacing loss and reestablishment thresholds.

    Related Concept Videos

    You might also read

    Related Articles

    Articles linked to this work by shared authors, journal, and citation graph.

    Sort by
    Same author

    HME coupled with FDM 3D printing of a customized oral solid form to treat pediatric epilepsy.

    International journal of pharmaceutics·2025
    Same author

    Publisher Correction: Live-cell three-dimensional single-molecule tracking reveals modulation of enhancer dynamics by NuRD.

    Nature structural & molecular biology·2023
    Same author

    Live-cell three-dimensional single-molecule tracking reveals modulation of enhancer dynamics by NuRD.

    Nature structural & molecular biology·2023
    Same author

    Clinical evaluation of anaesthetic-like effect of two dermocosmetic formulations containing Aquaphilus dolomiae extract-G3 in subjects with sensitive facial skin.

    Journal of the European Academy of Dermatology and Venereology : JEADV·2022
    Same author

    Essential omega-3 fatty acids tune microglial phagocytosis of synaptic elements in the mouse developing brain.

    Nature communications·2020
    Same author

    Maternal dietary omega-3 deficiency worsens the deleterious effects of prenatal inflammation on the gut-brain axis in the offspring across lifetime.

    Neuropsychopharmacology : official publication of the American College of Neuropsychopharmacology·2020

    Area of Science:

    • Biomedical Engineering
    • Cardiovascular Devices
    • Electrophysiology

    Background:

    • Cardiac pacing relies on tined leads to deliver electrical stimuli.
    • Accurate threshold determination is crucial for effective pacemaker function and patient safety.
    • The CPI 4118 tined lead is a commonly used device in cardiac pacing.

    Purpose of the Study:

    • To report the constant current and constant voltage thresholds for the CPI 4118 tined lead.
    • To evaluate external pacemakers and pacing system analyzers as threshold testing devices.
    • To investigate potential differences in pacing thresholds during stimulus reduction versus increase.

    Main Methods:

    • Thresholds were determined for CPI 4118 tined leads using both constant current and constant voltage modes.
    • Three external pacemakers and two pacing system analyzers were utilized for threshold testing.
    • A calibrated isolation amplifier was employed for analyzing stimulus current and voltage waveforms.

    Main Results:

    • In 98% of cases, constant current thresholds were ≤0.6 mA.
    • In 96% of cases, constant voltage thresholds were ≤0.5 V.
    • No significant difference was observed between pacing loss and reestablishment thresholds.

    Conclusions:

    • The CPI 4118 tined lead demonstrates low and consistent pacing thresholds.
    • The evaluated devices are suitable for threshold testing of these leads.
    • Further investigation may be needed to clarify the pacing loss and reestablishment threshold behavior.