Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Computed Tomography01:10

Computed Tomography

9.7K
Tomography refers to imaging by sections. Computed tomography (CT) is a non-invasive imaging technique that uses computers to analyze several cross-sectional X-rays to reveal minute details about structures in the body.
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
9.7K
Electron Microscope Tomography and Single-particle Reconstruction01:07

Electron Microscope Tomography and Single-particle Reconstruction

3.1K
Transmission electron microscopy (TEM) can be used to determine the 3D structure of biological samples with the help of techniques such as electron microscope tomography and single-particle reconstruction. While single-particle reconstruction can examine macromolecules and macromolecular complexes in vitro conditions only, tomography permits the study of cell components or small cells in vivo.
Electron Tomography
Electron tomography can be performed either in TEM or STEM (scanning transmission...
3.1K
Spherical Coordinates01:23

Spherical Coordinates

17.0K
Spherical coordinate systems are preferred over Cartesian, polar, or cylindrical coordinates for systems with spherical symmetry. For example, to describe the surface of a sphere, Cartesian coordinates require all three coordinates. On the other hand, the spherical coordinate system requires only one parameter: the sphere's radius. As a result, the complicated mathematical calculations become simple. Spherical coordinates are used in science and engineering applications like electric and...
17.0K

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Structural connectome analysis using a graph-based deep model for prediction of non-imaging variables.

Frontiers in neuroscience·2026
Same author

DEEP-LEARNING CORTICAL REGISTRATION GUIDED BY STRUCTURAL AND DIFFUSION MRI AND CONNECTIVITY.

Proceedings. IEEE International Symposium on Biomedical Imaging·2026
Same author

Diffusion MRI experimental design optimization for microstructure imaging.

Communications biology·2026
Same author

Joint Neural Network for Fast Retrospective Rigid Motion Correction of Accelerated Segmented Multislice MRI.

Proceedings of the International Society for Magnetic Resonance in Medicine ... Scientific Meeting and Exhibition. International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition·2026
Same author

Left Ventricular Geometry Improves Prediction of Sex-Specific Post-TAVR Remodeling in Aortic Stenosis.

medRxiv : the preprint server for health sciences·2026
Same author

Factors associated with severe neurological sequelae of COVID-19: findings from the multicenter COVID-BRAIN imaging cohort.

Frontiers in human neuroscience·2026
Same journal

LEARNABLE HIERARCHICAL VISUAL CONTEXTS FOR TUMOR SEGMENTATION IN COMPUTED TOMOGRAPHY IMAGES.

Proceedings. IEEE International Symposium on Biomedical Imaging·2026
Same journal

DUAL CROSS-ATTENTION SIAMESE TRANSFORMER FOR RECTAL TUMOR REGROWTH ASSESSMENT IN WATCH-AND-WAIT ENDOSCOPY.

Proceedings. IEEE International Symposium on Biomedical Imaging·2026
Same journal

LUMEN: LONGITUDINAL MULTI-MODAL RADIOLOGY MODEL FOR PROGNOSIS AND DIAGNOSIS.

Proceedings. IEEE International Symposium on Biomedical Imaging·2026
Same journal

OVERVIEW OF THE CXR-LT 2026 CHALLENGE: MULTI-CENTER LONG-TAILED AND ZERO SHOT CHEST X-RAY CLASSIFICATION.

Proceedings. IEEE International Symposium on Biomedical Imaging·2026
Same journal

CROSS-MODAL FINE-TUNING OF 3D CONVOLUTIONAL FOUNDATION MODELS FOR ADHD CLASSIFICATION WITH LOW-RANK ADAPTATION.

Proceedings. IEEE International Symposium on Biomedical Imaging·2026
Same journal

AN IN SILICO STUDY OF LOW-INTENSITY FOCUSED ULTRASOUND DISPLACEMENT MAPPING WITH A 220 KHZ CLINICAL PHASED-ARRAY TRANSDUCER.

Proceedings. IEEE International Symposium on Biomedical Imaging·2026
See all related articles

Related Experiment Video

Updated: Apr 16, 2026

Quantitative Optical Microscopy: Measurement of Cellular Biophysical Features with a Standard Optical Microscope
14:09

Quantitative Optical Microscopy: Measurement of Cellular Biophysical Features with a Standard Optical Microscope

Published on: April 7, 2014

16.3K

ODF RECONSTRUCTION IN Q-BALL IMAGING WITH SOLID ANGLE CONSIDERATION.

Iman Aganj1, Christophe Lenglet2, Guillermo Sapiro1

  • 1Department of Electrical and Computer Engineering, University of Minnesota, Minneapolis, MN, USA.

Proceedings. IEEE International Symposium on Biomedical Imaging
|March 20, 2015
PubMed
Summary
This summary is machine-generated.

This study introduces a mathematically correct method for calculating the orientation distribution function (ODF) in Q-ball imaging (QBI), improving fiber orientation analysis in diffusion MRI. The new approach provides normalized and sharper ODFs, reducing the need for post-processing in HARDI data.

Keywords:
Orientation distribution function (ODF)high angular resolution diffusion imaging (HARDI)magnetic resonance imaging (MRI)q-ball imaging (QBI)solid angle

More Related Videos

Determining 3D Flow Fields via Multi-camera Light Field Imaging
14:25

Determining 3D Flow Fields via Multi-camera Light Field Imaging

Published on: March 6, 2013

17.3K
Born Normalization for Fluorescence Optical Projection Tomography for Whole Heart Imaging
16:44

Born Normalization for Fluorescence Optical Projection Tomography for Whole Heart Imaging

Published on: June 2, 2009

10.8K

Related Experiment Videos

Last Updated: Apr 16, 2026

Quantitative Optical Microscopy: Measurement of Cellular Biophysical Features with a Standard Optical Microscope
14:09

Quantitative Optical Microscopy: Measurement of Cellular Biophysical Features with a Standard Optical Microscope

Published on: April 7, 2014

16.3K
Determining 3D Flow Fields via Multi-camera Light Field Imaging
14:25

Determining 3D Flow Fields via Multi-camera Light Field Imaging

Published on: March 6, 2013

17.3K
Born Normalization for Fluorescence Optical Projection Tomography for Whole Heart Imaging
16:44

Born Normalization for Fluorescence Optical Projection Tomography for Whole Heart Imaging

Published on: June 2, 2009

10.8K

Area of Science:

  • Medical Imaging
  • Neuroimaging
  • Diffusion MRI

Background:

  • Q-ball imaging (QBI) is a high angular resolution diffusion imaging (HARDI) technique used to resolve multiple intravoxel fiber orientations.
  • Standard ODF computation in QBI uses linear radial projection, which neglects volume element changes, leading to inaccurate, unnormalized, and less sharp ODFs.
  • Existing methods often require post-processing like sharpening or spherical deconvolution.

Purpose of the Study:

  • To derive a mathematically correct closed-form expression for the orientation distribution function (ODF) in Q-ball imaging.
  • To address the limitations of standard ODF computation in QBI, such as lack of normalization and sharpness.
  • To provide an efficient method for computing accurate ODFs from QBI data.

Main Methods:

  • Derivation of a closed-form expression for the ODF based on the mathematically correct definition.
  • Implementation of the derived ODF computation for QBI.
  • Validation using artificial data and real HARDI volumes.

Main Results:

  • A dimensionless and normalized ODF is derived for QBI.
  • The proposed method efficiently computes ODFs from q-ball acquisition protocols.
  • Demonstrated significantly improved performance on artificial and real HARDI data compared to standard methods.

Conclusions:

  • The derived ODF provides a more accurate representation of fiber orientations in QBI.
  • The method enhances the quality of HARDI data analysis by producing normalized and sharper ODFs.