Related Experiment Video
Updated: Apr 16, 2026

Novel Triple-Loop Technique for Suturing TFCC Injuries without Transosseous Tunnel
Published on: May 23, 2025
Graft diameter does not influence primary stability of ulnar collateral ligament reconstruction of the elbow
Jens Dargel1, Fabian Küpper, Kilian Wegmann
1Clinic for Orthopaedics and Trauma Surgery, University of Cologne, Joseph-Stelzmann Strasse 9, 50924, Cologne, Germany, jens.dargel@uk-koeln.de.
Background:
Ulnar collateral ligament insufficiency may result in medial elbow pain, instability, and reduced athletic performance in throwing athletes. Several reconstruction methods have been described, but biomechanical studies suggest that in general, stability of the graft construct is inferior to the native ulnar collateral ligament. This study investigates whether a stronger graft would yield greater resistance to valgus load over the range of motion.
Methods:
Ten cadaveric elbows were mounted to a testing fixture and incremental valgus moments of 2.5, 5, and 7.5 Nm were applied with the elbow in 120°, 90°, 60°, 30° and 0° of flexion and in varying rotational forearm positions. The intact and the ulnar collateral ligament released elbow joint were compared with the docking ulnar collateral ligament reconstruction technique, using different graft sources with increasing cross-sectional areas: palmaris longus, tricpes brachii, extensor carpi radialis longus, and semitendinosus. The resulting angular displacement was evaluated and compared between graft sources and different elbow positions.
Results:
Compared with the intact situation, ulnar collateral ligament release resulted in a significant increase in valgus deformation over the entire range of flexion-extension motion. Ligament reconstruction using any graft source significantly restored valgus stability at 60°, 90°, and 120°, while at 0° and 30°, angular valgus deformation did not significantly differ from the ulnar collateral ligament deficient situation. There were no significant differences in angular valgus deformation between the graft sources over the range of flexion motion or forearm rotation.
Conclusions:
This study did not prove that a thicker graft yielded more resistance to valgus moments when using the docking technique. Thicker grafts require larger bone tunnels, cannot be adequately tensioned, and are non-anatomic. Therefore, the palmaris longus or a triceps tendon strip are considered more appropriate for ulnar collateral ligament reconstruction.
More Related Videos
10:36Vascularized Composite Hand Allograft Procurement and Preparation for Distal and Proximal Forearm Allotransplantation: A Stepwise Approach
Published on: May 23, 2025
05:18Author Spotlight: Ultrasound-Guided Needle Release Combined with Corticosteroid Injection for the Treatment of Supinator Syndrome
Published on: May 26, 2023
Related Concept Videos
Bones of the Upper Limb: Ulna
Bones of the Upper Limb: Radius
The radius has a nail-shaped head, and a...
Bones of the Upper Limb: Humerus
Spinal Nerves: Plexus I
The Cervical Plexus
The cervical plexus, formed by the anterior rami of the first four...
Arteries of the Upper Limbs
Muscles that Move the Forearm
Forearm Flexors
The biceps brachii, brachialis, and brachioradialis are forearm flexors. The biceps brachii is made up of two heads. Its long head originates at the supraglenoid tubercle of the scapula, whereas that of the short head is...