Related Experiment Video
Updated: Apr 16, 2026

X-ray Dose Reduction through Adaptive Exposure in Fluoroscopic Imaging
Published on: September 11, 2011
Improved precision of exposure-response relationships by optimal dose-selection. Examples from studies of receptor
Matts Kågedal1, Mats O Karlsson, Andrew C Hooker
1Department of Pharmaceutical Biosciences, Uppsala University, Uppsala, Sweden, mattskagedal@gmail.com.
Abstract:
An understanding of the relationship between drug exposure and response is a fundamental basis for any dosing recommendation. We investigate optimal dose-selection for two different types of studies, a receptor occupancy study assessed by positron emission tomography (PET) and a dose-finding study in neuropathic pain treatment. For the PET-study, an inhibitory E-max model describes the relationship between drug exposure and displacement of a radioligand from specific receptors in the brain. The model has a mechanistic basis in the law of mass action and the affinity parameter (Ki PL ) is of primary interest. For optimization of the neuropathic pain study, the model is empirical and the exposure response curve itself is of primary interest. An alternative parameterization of the sigmoid Emax model was therefore used where the plasma concentration corresponding to the minimum relevant efficacy was estimated as a parameter. Optimal design methodology was applied using the D-optimal criterion as well as the Ds-optimal criterion where parameters of interest were defined. For the PET-study it was shown that the precision of Ki PL can be improved by inclusion of brain regions with both high and low receptor density and that the need for high doses is reduced when a brain region with low receptor density is included in the analysis. In the case of the neuropathic pain study it was shown that a Ds-optimal study design using the reparameterized Emax model can improve the precision in the minimum effective dose compared to a D-optimal design.
More Related Videos
10:33Expedited Radiation Biodosimetry by Automated Dicentric Chromosome Identification ADCI and Dose Estimation
Published on: September 4, 2017
06:20Irradiator Commissioning and Dosimetry for Assessment of LQ α and β Parameters, Radiation Dosing Schema, and in vivo Dose Deposition
Published on: March 11, 2021
Related Concept Videos
Dose-Response Relationship: Overview
Pharmacokinetic–Pharmacodynamic Relationship: Exposure, Response and Effect
Dose-Response Relationship: Selectivity and Specificity
Pharmacokinetic–Pharmacodynamic Relationship: Problems
Dose Response Curve: Conventional Versus Nonmonotonic
Dose Size and Dosing Frequency: Determination Methods