Related Experiment Video
Updated: Apr 16, 2026

Absolute Quantitation of Inositol Pyrophosphates by Capillary Electrophoresis Electrospray Ionization Mass Spectrometry
Published on: August 13, 2021
Electrospray ionization mass spectrometry for the quantification of inorganic cations and anions
Hiroki Hotta1, Kin-ichi Tsunoda
1Department of Chemistry, Nara University of Education.
Abstract:
Recent studies from our laboratory on electrospray ionization mass spectrometry (ESI-MS) for the quantification of inorganic cations and anions are reviewed. Metal ions were determined by ESI-MS in negative-ion mode as monovalent negative ions of their aminopolycarboxylate (APC) complexes, where excess amounts of the APC agents were added to sample solutions. Among the APCs studied, we found trans-1,2-diaminocyclohexane-N,N,N',N'-tetraacetic acid (CyDTA, the chemical forms in a complex were expressed as H(n)cydta(n-4)) as the best chelating agent. A size exclusion column was used for on-line separation of the metal-APC complexes from matrix salts in samples. Total amounts of Al, Ni, Cu, Zn, and Pb in the biological certified reference materials (CRM), Olive Leaves (BCR-062) and Plankton (BCR-414), and in a soil CRM (JSAC-0401) were successfully determined by the proposed method. Halide ions (X(-) = F(-), Cl(-), Br(-) and I(-)) and cyanide (CN(-)) were determined by ESI-MS based on the formation of ternary complexes of metals, chelating agents and the analyte anions. Negative ions of the ternary complexes of group 13 elements, nitrilotriacetic acid (NTA, H(n)nta(n-3)), and halides, i.e., [AlF(nta)](-) for F(-), and [InX(nta)](-) for other halides, were measured; the limits of detection (LODs) were 10 nmol dm(-3) for F(-), 0.31 μmol dm(-3) for Cl(-), 3.8 nmol dm(-3) for Br(-), and 1.6 nmol dm(-3) for I(-), respectively. In the case of CN(-), an LOD of 20 nmol dm(-3) was obtained based on measurements of the ternary complex of Cu(II), CN(-) and 4-(2-pyridylazo)resorcinol (PAR, Hnpar(n-2)), i.e., [(63)Cu(II)(CN)(par)](-) (m/z 302). Moreover, quantitative methods for Cr(VI) and Cr(III) by ESI-MS were developed, where HCrO4(-) (m/z 117) for Cr(VI) and [Cr(III)(cydta)](-) for Cr(III) were used for measurements.
More Related Videos
04:48Setup of Capillary Electrophoresis-Inductively Coupled Plasma Mass Spectrometry CE-ICP-MS for Quantification of Iron Redox Species FeII, FeIII
Published on: May 4, 2020
07:54Capillary Electrophoresis Mass Spectrometry Approaches for Characterization of the Protein and Metabolite Corona Acquired by Nanomaterials
Published on: October 27, 2020
Related Concept Videos
Electrospray Ionization (ESI) Mass Spectrometry
ESI utilizes electrical energy to transfer ions from the liquid phase of the sample into the...
Inductively Coupled Plasma–Mass Spectrometry (ICP–MS): Overview
Ion-Exchange Chromatography
Chemical Ionization (CI) Mass Spectrometry
Inductively Coupled Plasma-Mass Spectrometry (ICP-MS): Interferences
Electrogravimetric Analysis: Overview
To test the completeness of the...