Related Experiment Video
Updated: Apr 16, 2026

Flexible Colonoscopy in Mice to Evaluate the Severity of Colitis and Colorectal Tumors Using a Validated Endoscopic Scoring System
Published on: October 16, 2013
Simethicone to prevent colonic bubbles during CT colonography performed with polyethylene glycol lavage and iohexol
Gil-Sun Hong1, Seong Ho Park, Bohyun Kim
11 Department of Radiology and Research Institute of Radiology, University of Ulsan College of Medicine, Asan Medical Center, 88, Olympic-ro 43-gil, Songpa-gu, Seoul 138-736, Korea.
Objective:
The purpose of this study was to determine whether the occurrence of numerous colonic bubbles during CT colonography (CTC) performed with polyethylene glycol cleansing and oral iohexol fecal/fluid tagging could be prevented by use of simethicone.
Subjects And Methods:
Adults with suspected colonic neoplasia who had been randomly assigned to control and simethicone intervention groups underwent CTC after cleansing with 4 L of polyethylene glycol, tagging with 50 mL of 350 mg I/mL oral iohexol, and without (control) or with (intervention) oral administration of 200 mg of simethicone. Colonic segments in the control and intervention groups were evaluated for amount of colonic bubbles during CTC. A 6-point grading system was used in which 0 indicated no bubbles and 5 indicated that more than three fourths of the air-distended mucosa was covered with bubbles. The primary endpoint was a per-patient colonic bubble grade, derived as an average of the segmental grades.
Results:
Eighty adults with suspected colonic neoplasia were randomly assigned to the control (40 patients) and simethicone intervention (40 patients) groups. A total of 659 colonic segments in the control group and 689 segments in the intervention group were evaluated for amount of colonic bubbles during CTC. The per-patient colonic bubble score was significantly lower in the simethicone intervention group than in the control group. The mean score was 0.0±0.1 (SD) versus 1.2±0.8 (p<0.001; 95% CI for the mean difference, -1.4 to -1.0). In the intervention group, 673 (97.7%) segments were grade 0, and 16 (2.3%) were grade 1. In contrast, in the control group, 226 (34.3%) segments were grade 0; 173 (26.3%), grade 1; 175 (26.6%), grade 2; 45 (6.8%), grade 3; 23 (3.5%), grade 4; and 17 (2.6%), grade 5.
Conclusion:
The colonic bubbles associated with fecal/fluid tagging with iohexol can be successfully prevented by adding simethicone to the colonic preparation.
Related Concept Videos
Imaging Studies III: Gastrointestinal Motility Studies and Virtual Colonoscopy
Radionuclide Testing
Radionuclide testing is a sophisticated medical technique for assessing gastrointestinal motility. It focuses on gastric emptying and colonic transit time. Radioactive markers track the movement of food through the digestive system, providing insights into gastrointestinal disorders.
In gastric emptying studies, a meal's liquid and...
Drugs Affecting GI Tract Motility: Other Laxatives
Osmotic or saline laxatives, like magnesium hydroxide or milk of...
Drugs for Treatment of Constipation-Predominant IBS
Lower GI Series: Barium Enema
Procedure Details
The examination begins by inserting a lubricated rectal tube into the patient's rectum to administer a radiopaque barium solution. The barium flow is carefully...
Endoscopic Procedures II: Colonoscopy
Endoscopic Procedures IV: Sigmoidoscopy and Laproscopy
Sigmoidoscopy
Sigmoidoscopy is a diagnostic procedure that uses a flexible sigmoidoscope equipped with a light source and camera to examine the rectum and sigmoid colon. The procedure involves inserting the tube through the anus...

