"Surprise" Loading in Flexion Increases the Risk of Disc Herniation Due to Annulus-Endplate Junction Failure: A
Kelly R Wade1, Peter A Robertson, Ashvin Thambyah
1*Experimental Tissue Mechanics Laboratory, Department of Chemical and Materials Engineering, University of Auckland, Auckland, New Zealand; and †Department of Orthopaedic Surgery, Auckland City Hospital, Auckland, New Zealand.
Study Design:
Microstructural investigation of compression-induced herniation of the flexed lumbar disc.
Objective:
To provide a microstructural analysis of the mechanisms of annular wall failure in healthy discs subjected to flexion and a rate of compression comparable with the maximum rate at which the muscles of the spinal column can generate a force.
Summary Of Background Data:
Clinical evidence indicates the involvement of the endplate in herniation. It is known that both an elevated rate of compression and a flexed posture are necessary to cause disc failure either within the midspan of the annulus or at the annular-endplate interface. However, the question of what effect a sudden or "surprise" loading might have on the mode of failure is, as yet, unanswered.
Methods:
Twenty-four healthy mature ovine lumbar motion segments were compressed to failure in high physiological flexion (10º). This occurred over approximately 5 mm of crosshead displacement in 0.75 seconds that resulted in a displacement rate of 400 mm/min (defined as a "surprise" rate) and was intended to simulate the maximum rate at which the muscles of the spinal column can generate a force. The damaged discs were then analyzed microstructurally.
Results:
Fifty-eight percent of discs suffered annular-endplate junction rupture, 25% suffered midspan annular rupture, and the balance of 17% endplate fracture. Microstructural analysis indicated that annular rupture initiated at the endplate apical ridge in the mid-to-outer region of the annulus in both annular-endplate and midspan annulus rupture.
Conclusion:
Motion segments subjected to a "surprise" loading rate are likely to fail via some form of annular rupture. Failure under such sudden loading occurs mostly via rupture of the annular-endplate junction and is thought to arise from a rate-induced mechanostructural imbalance between the annulus and the endplate.
Level Of Evidence:
N/A.
More Related Videos
02:14Full Endoscopic Interlaminar Approach for Paracentral L5-S1 Disc Herniation
Published on: April 14, 2023
04:33Spinal Hernia Repair and Cauda Equina Repositioning After Lumbar Decompression under Three-Dimensional Microscopy: A Case Report and Literature Review
Published on: November 8, 2024
Related Concept Videos
Structural Joints: Cartilaginous Joints
There are two types of cartilaginous joints:
Synchondrosis
A synchondrosis ("joined by cartilage") is a cartilaginous joint where bones are connected by hyaline cartilage. Synchondrosis may be temporary...
Residual Stresses in Bending
Flexural Stress
Hooke's Law states that within the material's elastic limits, stress is directly proportional to strain. In a member experiencing a bending moment, the strain at any point is relative to its distance...
Plastic Deformations
Stress Concentrations in Circular Shafts
General Case of Eccentric Axial Loading
Consider a member subjected to equal and opposite forces that are applied along a line that does not coincide with the member's neutral axis. In unsymmetrical...