Drug-Induced Sleep Endoscopy DISE with Target Controlled Infusion TCI and Bispectral Analysis in Obstructive Sleep Apnea
Published on: December 6, 2016
Assessing the stability and safety of procedure during endoscopic submucosal dissection according to sedation
Chan Hyuk Park1, Seokyung Shin2, Sang Kil Lee1
1Division of Gastroenterology, Department of Internal Medicine, Severance Hospital, Institute of Gastroenterology, Yonsei University College of Medicine, Seoul, Korea.
Background:
Although endoscopic submucosal dissection (ESD) is routinely performed under sedation, the difference in ESD performance according to sedation method is not well known. This study attempted to prospectively assess and compare the satisfaction of the endoscopists and patient stability during ESD between two sedation methods.
Methods:
One hundred and fifty-four adult patients scheduled for ESD were sedated by either the IMIE (intermittent midazolam/propofol injection by endoscopist) or CPIA (continuous propofol infusion by anesthesiologist) method. The primary endpoint of this study was to compare the level of satisfaction of the endoscopists between the two groups. The secondary endpoints included level of satisfaction of the patients, patient's pain scores, events interfering with the procedure, incidence of unintended deep sedation, hemodynamic and respiratory events, and ESD outcomes and complications.
Results:
Level of satisfaction of the endoscopists was significantly higher in the CPIA Group compared to the IMIE group (IMIE vs. CPIA; high satisfaction score; 63.2% vs. 87.2%, P=0.001). The incidence of unintended deep sedation was significantly higher in the IMIE Group compared to the CPIA Group (IMIE vs. CPIA; 17.1% vs. 5.1%, P=0.018) as well as the number of patients showing spontaneous movement or those requiring physical restraint (IMIE vs. CPIA; spontaneous movement; 60.5% vs. 42.3%, P=0.024, physical restraint; 27.6% vs. 10.3%, P=0.006, respectively). In contrast, level of satisfaction of the patients were found to be significantly higher in the IMIE Group (IMIE vs. CPIA; high satisfaction score; 85.5% vs. 67.9%, P=0.027). Pain scores of the patients, hemodynamic and respiratory events, and ESD outcomes and complications were not different between the two groups.
Conclusion:
Continuous propofol and remifentanil infusion by an anesthesiologist during ESD can increase the satisfaction levels of the endoscopists by providing a more stable state of sedation.
Trial Registration:
ClinicalTrials.gov NCT01806753.
Related Concept Videos
Endoscopic Procedures IV: Sigmoidoscopy and Laproscopy
Sigmoidoscopy
Sigmoidoscopy is a diagnostic procedure that uses a flexible sigmoidoscope equipped with a light source and camera to examine the rectum and sigmoid colon. The procedure involves inserting the tube through the anus...
Stages of General Anesthesia
Endoscopic Procedures I: Esophagogastroduodenoscopy
During an EGD, the endoscope can be used to:
Endoscopic Procedures II: Colonoscopy
Parenteral Anesthetics: Overview
Skeletal Muscle Relaxants: Adverse Effects
Unlike...