Related Experiment Video
Updated: Apr 15, 2026

Oxygenation-sensitive Cardiac MRI with Vasoactive Breathing Maneuvers for the Non-invasive Assessment of Coronary Microvascular Dysfunction
Published on: August 17, 2022
Influence of Gadoxetate Disodium on Oxygen Saturation and Heart Rate during Dynamic Contrast-enhanced MR Imaging
Tatsuya Hayashi1, Satoshi Saitoh1, Yoshinori Tsuji1
1From the Department of Radiological Technology (T.H., Y.T., J.T., N.T., M.H., K.F., M.T.), Okinaka Memorial Institute for Medical Research (T.H., S.S., Y.T., J.T., N.T., M.H., K.F., M.T., H.K.), Department of Hepatology (S.S., H.K.), and Department of Radiology (S.S.), Toranomon Hospital, 2-2-2 Toranomon, Minato-ku, Tokyo 105-8470, Japan; and Division of Health Sciences, Graduate School of Medical Science, Kanazawa University, Kanazawa, Ishikawa, Japan (T.H., T.M.).
Purpose:
To investigate whether gadoxetate disodium affects peripheral capillary oxygen saturation (SpO2) and/or heart rate (HR) during dynamic contrast material-enhanced (DCE) magnetic resonance (MR) imaging in patients with liver diseases.
Materials And Methods:
This retrospective study was approved by the institutional review board, who waived the requirement for informed consent. Four hundred fifty-eight patients (171 women [mean age, 66.5 years; range, 23-87 years] and 287 men [mean age, 61.1 years; range, 25-89 years]) who underwent liver DCE MR imaging with gadoxetate disodium (0.025 mmol per kilogram of body weight) from October 28, 2013, to June 24, 2014, were included in this study. They were monitored for SpO2 and HR during DCE MR imaging. Motion artifact severity was graded by using a five-point scale, and transient severe motion (TSM) was defined by a score of at least 4. The association between TSM and baseline predictors was assessed, and HR and SpO2 at each postcontrast phase were compared with those at the precontrast phase in the TSM and non-TSM groups.
Results:
Four hundred thirty-six patients were included in the non-TSM group, and 22 were included in the TSM group. Although the motion score was the worst at the arterial phase, the observed mean differences in SpO2 and HR between the precontrast phase and the arterial phase were less than 1% and 5 beats per minute, respectively (mean SpO2 ± standard deviation for the non-TSM group, 96.7% ± 1.8 vs 96.9% ± 1.8 [P = .11]; SpO2 for the TSM group, 96.4% ± 1.6 vs 96.1% ± 1.6 [P > .99]) (HR for the non-TSM group, 68.9 beats per minute ± 12.4 vs 70.9 beats per minute ± 12.1 [P < .0001]; HR for the TSM group, 75.0 beats per minute ± 11.8 vs 79.9 beats per minute ± 10.2 [P < .0001]).
Conclusion:
Intravenous gadoxetate disodium (a weight-based dose) does not cause changes in SpO2 and HR that lead to image quality degradation.
More Related Videos
12:29Magnetic Resonance Imaging Quantification of Pulmonary Perfusion using Calibrated Arterial Spin Labeling
Published on: May 30, 2011
13:56The Use of Magnetic Resonance Spectroscopy as a Tool for the Measurement of Bi-hemispheric Transcranial Electric Stimulation Effects on Primary Motor Cortex Metabolism
Published on: November 19, 2014
Related Concept Videos
Magnetic Resonance Imaging
Imaging Studies for Cardiovascular System IV: CMRI
Radiological Investigation II: MRI and Ventilation Perfusion Scan
Magnetic Resonance Imaging (MRI) and Ventilation Perfusion Scans are two radiological investigations that offer detailed diagnostic images of the body, particularly lung structures.
MRI
MRI uses magnetic fields and radiofrequency signals to distinguish between normal and abnormal tissues. This technology provides a more detailed diagnostic image than CT scans, enabling it to characterize pulmonary nodules, stage bronchogenic carcinoma, and evaluate inflammatory activity in...
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is...
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...