Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Radioactive Decay and Radiometric Dating02:48

Radioactive Decay and Radiometric Dating

42.0K
Radioactivity is a spontaneous disintegration of an unstable nuclide and is a random process, as all the nuclei in the sample do not decay simultaneously. The number of disintegrations per unit time is called the activity (A), which is directly proportional to the number of nuclei in the sample. The decay constant (λ) is an average probability of decay per nucleus in unit time.
42.0K
Nuclear Stability03:18

Nuclear Stability

24.5K
Protons and neutrons, collectively called nucleons, are packed together tightly in a nucleus. With a radius of about 10−15 meters, a nucleus is quite small compared to the radius of the entire atom, which is about 10−10 meters. Nuclei are extremely dense compared to bulk matter, averaging 1.8 × 1014 grams per cubic centimeter. If the earth’s density were equal to the average nuclear density, the earth’s radius would be only about 200 meters.
To hold positively...
24.5K
Radiological Investigation III: Pulmonary Angiogram and PET Scan01:13

Radiological Investigation III: Pulmonary Angiogram and PET Scan

672
Radiological investigations are paramount in the diagnosis and management of various pulmonary diseases. Two essential investigations are the Pulmonary Angiogram and the Positron Emission Tomography (PET) Scan.
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
672
Radioactivity and Nuclear Equations03:18

Radioactivity and Nuclear Equations

29.9K
Nuclear chemistry is the study of reactions that involve changes in nuclear structure. The nucleus of an atom is composed of protons and, except for hydrogen, neutrons. The number of protons in the nucleus is called the atomic number (Z) of the element, and the sum of the number of protons and the number of neutrons is the mass number (A). Atoms with the same atomic number but different mass numbers are isotopes of the same element.
A nuclide of an element has a specific number of protons and...
29.9K
Biological Effects of Radiation02:59

Biological Effects of Radiation

19.9K
All radioactive nuclides emit high-energy particles or electromagnetic waves. When this radiation encounters living cells, it can cause heating, break chemical bonds, or ionize molecules. The most serious biological damage results when these radioactive emissions fragment or ionize molecules. For example, α and β particles emitted from nuclear decay reactions possess much higher energies than ordinary chemical bond energies. When these particles strike and penetrate matter, they...
19.9K
Isotopes and Radioisotopes01:28

Isotopes and Radioisotopes

13.9K
In the early 1900s, English chemist Frederick Soddy realized that an element could have atoms with different masses that were chemically indistinguishable. These different types are called isotopes — atoms of the same element that differ in mass. Isotopes differ in mass because they have different numbers of neutrons but are chemically identical because they have the same number of protons. Soddy was awarded the Nobel Prize in Chemistry in 1921 for this discovery.
An isotope containing...
13.9K

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Yttrium-90 measurements with radionuclide calibrators: Comparison to Monte Carlo models and geometry effects.

Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine·2026
Same author

Half-life and gamma-ray emission intensity measurements for <sup>227</sup>Th.

Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine·2026
Same author

Primary activity measurement of an Am-241 solution using microgram inkjet gravimetry and decay energy spectrometry.

Metrologia·2026
Same author

Characterization and Calibration of the iQID Digital Autoradiography System for Direct Quantitative Imaging of Beta-Emitters in Tissue Samples.

bioRxiv : the preprint server for biology·2026
Same author

Half-life and gamma-ray emission intensity measurements for <sup>225</sup>Ac and progeny.

Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine·2025
Same author

Spatial uniformity and resolution in inkjet-printed <sup>241</sup>Am phantoms imaged by digital autoradiography.

Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine·2025

Related Experiment Video

Updated: Apr 15, 2026

Automated 90Sr Separation and Preconcentration in a Lab-on-Valve System at Ppq Level
08:53

Automated 90Sr Separation and Preconcentration in a Lab-on-Valve System at Ppq Level

Published on: June 6, 2018

8.5K

Secondary standards for ²²³Ra revised.

Denis E Bergeron1, Jeffrey T Cessna1, Brian E Zimmerman1

  • 1Physical Measurement Laboratory, National Institute of Standards and Technology, Gaithersburg, MD 20899-8462, USA.

Applied Radiation and Isotopes : Including Data, Instrumentation and Methods for Use in Agriculture, Industry and Medicine
|March 28, 2015
PubMed
Summary

New dose calibrator settings from NIST correct a 10% error in activity readings. This study revisits 2010 data, providing updated calibration factors for accurate nuclear medicine measurements.

Keywords:
Data reevaluationDose calibrator dial settingsIonization chamberRa-223

More Related Videos

A Novel Technique for Raman Analysis of Highly Radioactive Samples Using Any Standard Micro-Raman Spectrometer
07:52

A Novel Technique for Raman Analysis of Highly Radioactive Samples Using Any Standard Micro-Raman Spectrometer

Published on: April 12, 2017

13.5K
Automated Radiochemical Synthesis of [18F]3F4AP: A Novel PET Tracer for Imaging Demyelinating Diseases
11:03

Automated Radiochemical Synthesis of [18F]3F4AP: A Novel PET Tracer for Imaging Demyelinating Diseases

Published on: May 29, 2017

10.6K

Related Experiment Videos

Last Updated: Apr 15, 2026

Automated 90Sr Separation and Preconcentration in a Lab-on-Valve System at Ppq Level
08:53

Automated 90Sr Separation and Preconcentration in a Lab-on-Valve System at Ppq Level

Published on: June 6, 2018

8.5K
A Novel Technique for Raman Analysis of Highly Radioactive Samples Using Any Standard Micro-Raman Spectrometer
07:52

A Novel Technique for Raman Analysis of Highly Radioactive Samples Using Any Standard Micro-Raman Spectrometer

Published on: April 12, 2017

13.5K
Automated Radiochemical Synthesis of [18F]3F4AP: A Novel PET Tracer for Imaging Demyelinating Diseases
11:03

Automated Radiochemical Synthesis of [18F]3F4AP: A Novel PET Tracer for Imaging Demyelinating Diseases

Published on: May 29, 2017

10.6K

Area of Science:

  • Nuclear Medicine
  • Metrology
  • Radiopharmaceutical Calibration

Background:

  • Previous NIST-published dose calibrator settings from 2010 were found to be inaccurate.
  • A critical error in the calibration chain led to underestimated radiopharmaceutical activity readings by approximately 10%.

Purpose of the Study:

  • To report new, accurate calibration factors for dose calibrators.
  • To re-evaluate previous calibration data in light of a newly discovered error.
  • To provide revised calibration factors for various clinical geometries.

Main Methods:

  • Directly linking new calibration factors to updated NIST primary standards.
  • Revisiting and re-analyzing raw data from the original 2010 calibration experiments.
  • Comparing new experimental results with revised calibration factors.

Main Results:

  • New calibration factors, directly traceable to current NIST standards, have been determined.
  • Re-evaluation confirmed the necessity for correction, validating the new factors.
  • Revised calibration factors for multiple clinical geometries are presented.

Conclusions:

  • The previously reported 2010 dose calibrator settings are confirmed to be erroneous, causing a ~10% underestimation of activity.
  • Updated calibration factors are provided, ensuring more accurate radiopharmaceutical measurements.
  • The fundamental conclusions regarding geometry effects from the 2010 study remain valid.