Measurements of jet vetoes and azimuthal decorrelations in dijet events produced in [Formula: see text] collisions at

, G Aad1, B Abbott2

  • 1CPPM, Aix-Marseille Université and CNRS/IN2P3, Marseille, France.

The European Physical Journal. C, Particles and Fields
|March 28, 2015
PubMed

Related Concept Videos

Atomic Emission Spectroscopy: Interference01:30

Atomic Emission Spectroscopy: Interference

In atomic emission spectroscopy (AES), high-temperature atomizers excite a broad range of elements and molecules that generate complex emissions from sources such as oxides, hydroxides, and flame combustion products in the flame or plasma. Several strategies can be employed to minimize spectral interferences caused by overlapping emission lines or bands. These include increasing instrument resolution, choosing alternative emission lines, optimally placing the detector in low-background regions,...
771
Azimuths and Bearings01:19

Azimuths and Bearings

Azimuths and bearings are essential concepts in surveying, providing methods to express the direction of a line relative to a meridian. Azimuths refer to the clockwise angle measured from the north end of a reference meridian to the given line, ranging from zero to 360 degrees. This method gives a comprehensive directional reference within a full 360-degree circle, making it a straightforward way to communicate direction in various fields, including navigation, cartography, and...
986
Atomic Emission Spectroscopy: Instrumentation01:22

Atomic Emission Spectroscopy: Instrumentation

The instrumentation of atomic emission spectrometry (AES) involves various components, including atomization devices that convert samples into gas-phase atoms and ions. There are two main types of atomization devices: continuous and discrete atomizers.  Continuous atomizers, like plasmas and flames, introduce samples in a constant stream, while discrete atomizers inject individual samples using syringes or autosamplers. The most common discrete atomizer is the electrothermal atomizer.
1.6K
Atomic Absorption Spectroscopy: Interference01:25

Atomic Absorption Spectroscopy: Interference

Interference leads to systematic error in atomic absorption (AA) measurements by enhancing or diminishing the analytical signal or the background. These interferences can be grouped into three main categories: spectral interference, chemical interference, and physical interference.
Spectral interference occurs when signals from other elements or molecules overlap with the analyte signal, falsely elevating or masking the analyte's absorbance. This interference can be corrected using Zeeman,...
2.4K
Mass Analyzers: Overview01:13

Mass Analyzers: Overview

The mass analyzer is a crucial component of the mass spectrometer. In the ionization chamber, the vaporized sample is bombarded with a high-energy electron beam to generate a radical cation and further fragment into neutral molecules, radicals, and cations. A series of negatively charged accelerator plates accelerate the cations into the mass analyzer. The mass analyzer separates ions according to their mass-to-charge (m/z) ratios and then directs them to the detector. The common types of mass...
2.1K
Mass Analyzers: Common Types01:19

Mass Analyzers: Common Types

The quadrupole mass analyzer consists of four cylindrical metal rods arranged in a diamond carrying a DC voltage and a radio-frequency AC voltage. The motion of ions through the quadrupole depends on the field strength, causing only ions of a certain m/z to resonate successfully and strike the detector at a given field strength. Though the transmission rate for these analyzers is high, the exact elemental composition of the sample is not determined because of low resolution; however, they are...
2.0K