Radiological protection in computed tomography and cone beam computed tomography
1Massachusetts General Hospital and Harvard Medical School, Boston, USA madan.rehani@gmail.com.
The International Commission on Radiological Protection (ICRP) addresses rising patient radiation doses in computed tomography (CT) and cone beam CT (CBCT). New guidance is needed due to challenges like lack of standardization and user training in CBCT.
Area of Science:
- Radiological Physics
- Medical Imaging Safety
- Radiation Protection
Background:
- The International Commission on Radiological Protection (ICRP) has previously published guidance on patient dose management in computed tomography (CT) and multi-detector CT (MDCT).
- Increasing patient doses in CT were identified, prompting recommendations for manufacturers and users, emphasizing integrated safety features.
- Emerging cone beam CT (CBCT) systems present new radiological protection challenges due to their geometry and expanding use, often by untrained personnel.
Purpose of the Study:
- To address the radiological protection issues associated with cone beam CT (CBCT) systems.
- To summarize previous approaches for CT and MDCT and present preliminary information on new ICRP work for CBCT.
- To highlight critical challenges in CBCT radiation safety.
Main Methods:
- Review of established radiological protection strategies for conventional CT and MDCT.
- Identification and analysis of specific issues related to CBCT by an ICRP task group.
- Synthesis of preliminary findings and published work on CBCT radiation protection.
Main Results:
- Identified key CBCT challenges: lack of standardized dosimetry, misconception of low dose, insufficient user training, and inadequate dose information/tracking.
- Highlighted that some CBCT applications, like C-arm CT in interventional procedures, involve higher patient doses than often perceived.
- Established a foundation for updated guidance on CBCT radiological protection.
Conclusions:
- There is a critical need for standardized dosimetry and improved radiological protection practices in CBCT.
- Addressing the misconception of CBCT as inherently low-dose is essential for patient safety.
- Enhanced training and dose monitoring are crucial for safe CBCT utilization across medical and dental fields.
More Related Videos
11:31Using Micro-computed Tomography for the Assessment of Tumor Development and Follow-up of Response to Treatment in a Mouse Model of Lung Cancer
Published on: May 20, 2016
09:49Dual-phase Cone-beam Computed Tomography to See, Reach, and Treat Hepatocellular Carcinoma during Drug-eluting Beads Transarterial Chemo-embolization
Published on: December 2, 2013
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Radiological Investigation I: X-ray and CT
X-ray Imaging
Imaging Studies III: Computed Tomography
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...