Fluorescein gonioangiography of the normal canine eye using a dSLR camera adaptor
Anthony F Alario1, Christopher G Pirie1
1Department of Clinical Sciences, Tufts Cummings School of Veterinary Medicine, North Grafton, MA, USA.
Abstract:
The purpose of this study was to describe fluorescein gonioangiography (FGA) of the normal canine eye using a digital single lens reflex (dSLR) camera adaptor. Dogs were anesthetized using intravenous propofol. Imaging was performed using a Lovac Barkan goniolens, dSLR camera, dSLR camera adaptor, camera lens, and accessory flash. Twelve dogs with a mean age of 2.0 +/- 0.8 years were imaged. No characteristic angiographic phases were observed. Leakage from the peri-limbal capillary network was a common finding and occurred 7.7 +/- 2.2 s post injection in 9 (75%) dogs. In 3 (25%) dogs, filling of the circumferential ciliary artery was observed 10.3 +/- 2.8 s post injection. Dye leakage within the iris base and into the aqueous humor was demonstrated in 4 (33%) and 6 dogs (50%) respectively. No adverse events were noted. This study demonstrates FGA findings in normal canine eyes using a cost effective dSLR camera adaptor.