Related Experiment Video
Updated: Apr 15, 2026

A Minimally Invasive Model to Analyze Endochondral Fracture Healing in Mice Under Standardized Biomechanical Conditions
Published on: March 22, 2018
Morphometric analysis of distal interphalangeal joint and implications for arthrodesis with a headless compression
Benjamin Braun1, Andrew Bogle, Ethan Wiesler
1Department of Orthopaedic Surgery,Wake Forest School of Medicine, Winston Salem, North Carolina.
Abstract:
Using radiographs of a cross section of patients, measurements of phalanges were done to aid in surgical planning for distal interphalangeal joint (DIPJ) arthrodesis using a headless compression screw. Measurements were performed of the distal and middle phalanx of all fingers and the proximal and distal phalanx of the thumb. Three independent reviewers measured 50 patients. The average measurements (in mm) of anteroposterior (AP) dimensions were as follows: for the thumb P1 and P2: 5.7 and 5.5, lateral 4.2 and 3.5; for the index P2 and P3 AP: 4.2 and 3.3, lateral 2.1 and 1.8; for the long P2 and P3 AP: 4.5 and 3.5, lateral 2.2 and 1.8; for the ring P2 and P3 AP: 4.3 and 3.1, lateral 1.8 and 1.7; and for the small P2 and P3 AP: 3.7 and 2.2, lateral 1.8 and 1.5. Careful surgical planning by measuring the involved digit and knowledge of screw size is paramount to avoid complications from DIPJ arthrodesis with a compression screw.