Computerized Dynamic Posturography for Postural Control Assessment in Patients with Intermittent Claudication
Published on: December 11, 2013
Test-retest reliability of postural stability on two different foam pads
Chia-Cheng Lin1, Jennica L Roche2, Daniel P Steed2
1University of Pittsburgh, Department of Physical Therapy, Pittsburgh, PA, USA ; East Carolina University, Department of Physical Therapy, Greenville, NC, USA.
This study assessed the reliability of foam pads for postural control testing. Both Airex and Neurocom foam pads offer fair to good reliability, with Airex showing slightly better results for eyes-closed conditions.
Area of Science:
- Biomechanics
- Human Movement Science
- Clinical Assessment Tools
Background:
- Foam pads are widely utilized in clinical and laboratory settings for assessing postural control.
- Existing literature lacks comparative reliability data for different foam pad types.
- Standardized assessment of postural sway requires reliable testing surfaces.
Purpose of the Study:
- To evaluate the test-retest reliability of postural sway parameters using two common foam pad types: Airex and Neurocom.
- To determine the optimal foam surface for consistent and effective postural perturbation.
- To provide data supporting the selection of foam pads for postural control assessments.
Main Methods:
- Test-retest reliability study design.
- Participants: Ten healthy young adults.
- Measures: Postural sway collected using the Balance Accelerometry Measure device over 90 seconds (eyes open/closed) on firm, Airex foam, and Neurocom foam surfaces.
- Analysis: Intraclass correlation coefficients (ICC) calculated to assess reliability.
Main Results:
- Firm surface: Fair to good reliability for path length (ICC = 0.61-0.64).
- Airex foam: Fair to excellent reliability for path length (ICC = 0.41-0.81).
- Neurocom foam: Fair to good reliability for path length (ICC = 0.29-0.45).
Conclusions:
- Both Airex and Neurocom foam pads demonstrate acceptable test-retest reliability for postural sway assessment.
- Airex foam exhibited higher reliability scores compared to Neurocom foam, particularly with eyes closed.
- Both foam types appear to yield repeatable postural sway measurements, supporting their use in clinical practice.