Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Transformations of Functions II01:29

Transformations of Functions II

264
Transformations in mathematics alter the position or orientation of a function’s graph while preserving its fundamental shape. One important type of transformation is the horizontal shift, which involves modifying the input variable within a function’s equation. This operation affects where outputs occur along the horizontal axis but does not alter the function’s overall structure.A horizontal shift is achieved by replacing the input variable x with either x + c or x - c,...
264
Phase Contrast and Differential Interference Contrast Microscopy01:26

Phase Contrast and Differential Interference Contrast Microscopy

15.3K
Phase-Contrast Microscopes
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
15.3K

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Prevalence and in-hospital outcomes of diabetes among patients with acute coronary syndrome in China: findings from the Improving Care for Cardiovascular Disease in China-Acute Coronary Syndrome Project.

Cardiovascular diabetology·2018
Same author

Outcomes of different rehabilitative procedures in patients with pulmonary atresia, ventricular septal defect and major aortopulmonary collateral arteries.

European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery·2018
Same author

Impact of three-dimensional visualization technology on surgical strategies in complex hepatic cancer.

Bioscience trends·2018
Same author

Epidemiology of cardiovascular disease in China: current features and implications.

Nature reviews. Cardiology·2018
Same author

Prevalence of and Risk Factors for Peripheral Neuropathy in Chinese Patients With Diabetes: A Multicenter Cross-Sectional Study.

Frontiers in endocrinology·2018
Same author

Anti-neuroinflammatory Effects of 12-Dehydrogingerdione in LPS-Activated Microglia through Inhibiting Akt/IKK/NF-κB Pathway and Activating Nrf-2/HO-1 Pathway.

Biomolecules & therapeutics·2018

Related Experiment Video

Updated: Apr 15, 2026

Time Multiplexing Super Resolving Technique for Imaging from a Moving Platform
06:25

Time Multiplexing Super Resolving Technique for Imaging from a Moving Platform

Published on: February 12, 2014

8.9K

A novel multi-digital camera system based on tilt-shift photography technology.

Tao Sun1, Jun-Yong Fang2, Dong Zhao3

  • 1Key Laboratory of Technology in Geo-spatial Information Processing and Application System, Institute of Electronics, Chinese Academy of Sciences, Beijing 100190, China. ts-1@live.cn.

Sensors (Basel, Switzerland)
|April 4, 2015
PubMed
Summary

This study introduces a new multi-digital camera system (MDCS) using tilt-shift cameras (TSC) for improved high-accuracy spatial data acquisition. The proposed MDCS achieved 0.3m geo-position accuracy, surpassing traditional systems.

More Related Videos

A TIRF Microscopy Technique for Real-time, Simultaneous Imaging of the TCR and its Associated Signaling Proteins
16:10

A TIRF Microscopy Technique for Real-time, Simultaneous Imaging of the TCR and its Associated Signaling Proteins

Published on: March 22, 2012

24.6K
Preparation and Observation of Thick Biological Samples by Scanning Transmission Electron Tomography
08:04

Preparation and Observation of Thick Biological Samples by Scanning Transmission Electron Tomography

Published on: March 12, 2017

10.0K

Related Experiment Videos

Last Updated: Apr 15, 2026

Time Multiplexing Super Resolving Technique for Imaging from a Moving Platform
06:25

Time Multiplexing Super Resolving Technique for Imaging from a Moving Platform

Published on: February 12, 2014

8.9K
A TIRF Microscopy Technique for Real-time, Simultaneous Imaging of the TCR and its Associated Signaling Proteins
16:10

A TIRF Microscopy Technique for Real-time, Simultaneous Imaging of the TCR and its Associated Signaling Proteins

Published on: March 22, 2012

24.6K
Preparation and Observation of Thick Biological Samples by Scanning Transmission Electron Tomography
08:04

Preparation and Observation of Thick Biological Samples by Scanning Transmission Electron Tomography

Published on: March 12, 2017

10.0K

Area of Science:

  • Photogrammetry and Remote Sensing
  • Geospatial Data Acquisition
  • Optical Engineering

Background:

  • Traditional multi-digital camera systems (MDCS) face limitations in acquiring high-resolution spatial data.
  • Increasing demands for precise geospatial information necessitate advancements in camera system technology.

Purpose of the Study:

  • To propose and validate a novel category of MDCS utilizing tilt-shift photography (TSC) for enhanced spatial data accuracy.
  • To address the insufficiencies of conventional MDCS by integrating TSC capabilities.

Main Methods:

  • Development of a prototype MDCS with 2-4 Nikon D90 tilt-shift cameras.
  • Implementation of indoor control fields and calibration methods, including the digital distortion model (DDM) and a two-step calibrated strategy.
  • Analysis of TSC characteristics, such as edge distortion, through calibration experiments.

Main Results:

  • Flight experiments demonstrated the prototype system's capability to achieve 0.3m geo-position accuracy at 800m flight height and 0.15m spatial resolution.
  • Comparison with a traditional system (MADC II) showed the proposed MDCS yielding higher accuracy (0.3m vs. 0.6m).

Conclusions:

  • The proposed MDCS based on tilt-shift photography significantly improves the accuracy of spatial data acquisition.
  • Further enhancements in TSC accuracy are expected to yield even higher accuracy in photogrammetric products.
  • The study validates the feasibility and correctness of the novel MDCS approach for high-accuracy geospatial applications.