Related Experiment Video
Updated: Apr 15, 2026

Lab-Scale Model to Evaluate Odor and Gas Concentrations Emitted by Deep Bedded Pack Manure
Published on: July 19, 2018
Stall cleanliness and stall temperature of two different freestall bases
B A Wadsworth1, A E Stone1, J D Clark1
1Department of Animal and Food Sciences, University of Kentucky, Lexington 40546.
Abstract:
The objective of this study was to describe the differences in freestall cleanliness and stall temperature between a barn with Dual Chamber Cow Waterbeds (DCCW; Advanced Comfort Technology, Reedsburg, WI) and a barn with rubber-filled mattresses at the University of Kentucky Coldstream Dairy Research Farm from January 18, 2012, to May 3, 2013. Stall cleanliness was measured twice weekly (n=134) by the same 2 observers using a 0.91 m×0.91 m wire grid containing 128 equally sized rectangles (10.16 cm×5.08 cm). This grid was centered at the rear portion of the stall; a rectangle that was visibly wet or had any amount of feces present was defined as a dirty rectangle. Weekly stall temperature (n=66) was measured by the same observer during a.m. milkings in the same predetermined stalls. Feces and wet sawdust were removed from the stalls before stall temperatures were acquired. Temperatures were obtained using a handheld thermometer at 30.48 cm above the stall base as determined via dual laser measurements. Stall temperature was measured on the front, middle, and back of the stall first with clean sawdust and then with the sawdust removed from the stall and wiped clean with a towel. Daily temperature-humidity index (THI) was calculated using Kentucky climate data calculated through the University of Kentucky College of Agriculture via a data logger, located 5.63 km from the Coldstream Dairy Farm. Stall cleanliness was not different between the DCCW barn (26.09±0.89 rectangles) and the rubber-filled mattress barn (23.70±0.89 rectangles). Mean THI throughout the study was 64.39±0.82. Stall temperature was different among THI categories. Temperature-humidity index categories 1 (coldest), 2, 3, and 4 (warmest) had THI ranges of 22.94 to 50.77, 50.77 to 64.88, 64.88 to 78.75, and 78.75 to 101.59, respectively. Stall temperatures (°C; least squares means±SE) were 2.26±0.30, 8.86±0.30, 15.52±0.30, and 20.95±0.30 for THI categories 1 to 4, respectively. Stalls with rubber-filled mattresses had a lower temperature (°C) than DCCW with least squares means±SE of 10.52±0.21°C and 13.29±0.21°C, respectively. The DCCW were probably significantly warmer because water holds heat well. The DCCW may have more of a heat-insulating effect compared with rubber-filled mattresses.
Related Concept Videos
Assessing Body Temperature - Rectal
Follow these steps for rectal temperature assessment:
Step 1: Perform hand hygiene and don clean gloves to prevent cross-infection.
Step 2: Position the patient in a side-lying position to better visualize the rectal...
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Masonry in Cold and Hot Weather Conditions
Other key practices include keeping masonry units...
Assessing Body Temperature - Tympanic membrane
Step 1: Begin by practicing good hand hygiene to prevent the transmission of microorganisms.
Step 2: Turn on the thermometer and wait until the ready sign appears on the screen to ensure accurate measurement.
Step 3: Slide the probe cover in place to prevent cross-contamination.
Step 4: Instruct the patient to tilt their head to the side for comfort and check for cerumen...
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's...

