Related Experiment Video
Updated: Apr 15, 2026

A New Technique for Treating Low-risk Prostate Cancer—Super Active Surveillance
Published on: November 7, 2025
Role for (11)C-choline PET in active surveillance of prostate cancer
Oleksandr Boychak1, Larissa Vos2, William Makis3
1Division of Radiation Oncology, Department of Oncology, University of Alberta, Edmonton, AB;
Introduction:
Active surveillance (AS) is an increasingly popular management strategy for men diagnosed with low-risk indolent prostate cancer. Current tests (prostate-specific antigen [PSA], clinical staging, and prostate biopsies) to monitor indolent disease lack accuracy. (11)C-choline positron emission tomography (PET) has excellent detection rates in local and distant recurrence of prostate cancer. We examine (11)C-choline PET for identifying aggressive prostate cancer warranting treatment in the AS setting.
Methods:
In total, 24 patients on AS had clinical assessment and PSA testing every 6 months and (11)C-choline PET and prostate biopsies annually. The sensitivity and specificity to identify prostate cancer and progressive disease (PD) were calculated for each (11)C-choline PET scan.
Results:
In total, 62 biopsy-paired, serial (11)C-choline PET scans were analyzed using a series of standard uptake value-maximum (SUVmax) cut-off thresholds. During follow-up (mean 25.3 months), 11 of the 24 low-risk prostate cancer patients developed PD and received definitive treatment. The prostate cancer detection rate with (11)C-choline PET had moderate sensitivity (72.1%), but low specificity (45.0%). PD prediction from baseline (11)C-choline PET had satisfactory sensitivity (81.8%), but low specificity (38.5%). The addition of clinical parameters to the baseline (11)C-choline PET improved specificity (69.2%), with a slight reduction in sensitivity (72.7%) for PD prediction.
Conclusions:
Addition of (11)C-choline PET imaging during AS may help to identify aggressive disease earlier than traditional methods. However, (11)C-choline PET alone has low specificity due to overlap of SUV values with benign pathologies. Triaging low-risk prostate cancer patients into AS versus therapy will require further optimization of PET protocols or consideration of alternative strategies (i.e., magnetic resonance imaging, biomarkers).