Related Experiment Video
Updated: Apr 15, 2026

09:36
Measurement of Spatial Stability in Precision Grip
Published on: June 4, 2020
3.6K
Normative Values for Grip and Pinch Strength for 6- to 19-Year-Olds
Victoria A McQuiddy1, Carol R Scheerer2, Ryan Lavalley2
1Division of Occupational and Physical Therapy, Cincinnati Children's Hospital Medical Center, Cincinnati, OH.
Archives of Physical Medicine and Rehabilitation
|April 8, 2015
Summary
Updated grip and pinch strength data for ages 6-19 show significant differences from previous norms. Age and sex impact hand strength, with males generally stronger, but hand dominance does not significantly affect results.
Area of Science:
- Pediatric rehabilitation
- Human motor development
- Biometrics
Background:
- Accurate normative data for grip and pinch strength are essential for assessing pediatric and young adult hand function.
- Previous normative values may no longer reflect current population capabilities.
Purpose of the Study:
- To establish current grip and pinch strength norms for individuals aged 6 to 19 years.
- To investigate the influence of age, sex, and hand dominance on these strength measures.
Main Methods:
- A descriptive, cross-sectional study involving 1508 male and female students aged 6 to 19 years.
- Grip, tip pinch, lateral pinch, and palmar pinch strengths were measured.
- Data were analyzed using analysis of covariance and 2-sample t tests, stratified by age and sex.
Main Results:
- Both age and sex significantly influenced hand strength, with strength increasing with age and being greater in males.
- Hand dominance did not show a significant effect on hand strength.
- Current normative values were significantly lower than those published 28 years ago.
Conclusions:
- Updated normative data for grip and pinch strength are crucial for rehabilitation practitioners.
- These updated norms allow for more accurate assessment of impairment and progress tracking in young individuals.
- The study highlights the necessity of regularly updating normative strength data due to observed changes over time.
Related Concept Videos
Moment of a Force: Problem Solving
1.4K
Understanding the scalar formulation of the moment of a force and applying it correctly through problem-solving is crucial in designing and analyzing mechanical systems. Here are the steps for problem-solving with the moment of a force:
1.4K
Strength of Cement
814
Strength tests for cement are not performed directly on neat cement paste due to difficulty in obtaining consistent, reliable specimens. Instead, cement is typically tested in the form of cement-sand mortar.
For compressive strength tests, ASTM C 109-05 standards prescribe a cement-sand mix ratio of 1:2.75 and a water/cement ratio of 0.485 for making 2-inch cubes. These cubes are mixed, cast, and cured in saturated lime water at 23°C until testing. Flexural strength testing, outlined in...
For compressive strength tests, ASTM C 109-05 standards prescribe a cement-sand mix ratio of 1:2.75 and a water/cement ratio of 0.485 for making 2-inch cubes. These cubes are mixed, cast, and cured in saturated lime water at 23°C until testing. Flexural strength testing, outlined in...
814

