Aim:
To assess validity and reliability of the German version of the Individualized Care Scale (ICS).
Background:
Individualized nursing care plays a pivotal role in establishing patient-centered care. To assess individualized nursing care and to compare it in different settings and countries, valid and reliable instruments are needed. No psychometric-tested instrument for comparing individualized nursing care with other countries is available in Germany.
Design:
Cross-sectional study.
Methods:
Data were collected between September 2013 and June 2014 from 606 patients in 20 wards in five hospitals across Germany. Unidimensionality of the ICS scales ICSA (patients' views on how individuality is supported through nursing interventions) and ICSB (patients' perceptions of individualized nursing care) was analyzed by confirmatory factor analysis. Internal consistency was assessed by calculating Cronbach's alpha. The Smoliner Scale (patients' perceptions of the decision-making process in nursing care) and results from participating hospitals' assessment of the nursing care delivery systems were used to assess known-groups validity and concurrent validity.
Results:
Fit indices of confirmatory factor analysis indicate unidimensionality of the ICSA (Comparative Fit Index: 0.92; Tucker-Lewis Index: 0.902; root mean square error of approximation: 0.09; standardized root mean square residual: 0.05) and the ICSB (Comparative Fit Index: 0.91; Tucker-Lewis Index: 0.89; root mean square error of approximation: 0.09; standardized root mean square residual: 0.05). Internal consistency using Cronbach's alpha was 0.95 (95% confidence interval: 0.94-0.95) for ICSA and 0.93 (95% confidence interval: 0.92-0.94) for the ICSB. Concurrent validity was established by a significant relationship between the Smoliner Scale and ICSA (r=0.66; P<0.01) and ICSB (r=0.72; P<0.01). Known-groups validity was approved by ICSA/ICSB score differences related to nursing care delivery systems and patients' perceptions of decision-making style.
Conclusion:
The German version of the ICS is deemed a valid and reliable instrument for use in practice and research with hospitalized patients.
More Related Videos
10:39Qualitative and Quantitative Validation of Tools with Rating Scales Aimed at Assessing the Quality of University Service-Learning
Published on: August 29, 2025
06:52Assessment of Dependence in Activities of Daily Living Among Older Patients in an Acute Care Unit
Published on: September 30, 2020
Related Concept Videos
Reliability and Validity
Data Validation
Nursing assessment guides are generally based on holistic models rather than medical...
Nursing Clinical Information System
A Nursing Clinical Information System (NCIS) is a specialized type of healthcare information system tailored to meet the unique needs of nursing practice. It incorporates the principles of nursing informatics to streamline information management and improve the quality of care delivery.
Critical attributes of NCIS include:
Self-Report Tests of Personality
Documentation in Long-Term and Home Healthcare Setting
Long-Term Care Facilities
Dosage Regimen: Individualization