Alternative Method of Retrocrural Approach during Celiac Plexus Block Using a Bent Tip Needle
Ji Won An1, Eun Kyeong Choi1, Chol Hee Park1
1Department of Anesthesiology and Pain Medicine, Anesthesia and Pain Research Institute, Yonsei University College of Medicine, Seoul, Korea.
The Korean Journal of Pain
|April 9, 2015
Summary
This study determined safe needle angles and entry points for celiac plexus block (CPB) using CT scans. A bent tip needle allowed for safer CPB with reduced parameter values.
Area of Science:
- Interventional Radiology
- Pain Management
- Anatomy
Background:
- Computed tomography (CT) scans were reviewed to establish safe parameters for celiac plexus block (CPB).
- The study aimed to define safe ranges for needle angle, skin entry point, and length.
- The utility of a bent tip needle in CPB was also evaluated.
Purpose of the Study:
- Determine safe oblique angles, skin entry points, and needle lengths for celiac plexus block (CPB).
- Evaluate the effectiveness of a bent tip needle in performing CPB.
- Correlate anatomical parameters with patient characteristics like BMI.
Main Methods:
- CT scans of 60 CPB patients were analyzed.
- Measurements included minimal/maximal oblique angles and midline-to-puncture distances using the L2 vertebral body.
- Three-dimensional measurements calculated imaginary needle trajectory distances; a bent tip needle's actual puncture site distance was also recorded.
Main Results:
- Identified safe imaginary oblique angle ranges (26.4-36.0°) and midline-to-puncture distances (6.1-7.6 cm).
- Needle trajectory distances ranged from 9.5-11.6 cm.
- Bent tip needle procedures resulted in smaller measured distances (5.0-6.5 cm), with parameters correlating to BMI, except for GF/G'F. Mild, transient complications were observed.
Conclusions:
- Established safe parameter values for straight needle celiac plexus block (CPB).
- A bent tip needle, used with 20° oblique fluoroscopy, enabled safe CPB with reduced parameter values.
- The findings contribute to optimizing CPB technique and safety.