Related Experiment Video
Updated: Apr 15, 2026

Paradigms of Lower Extremity Electrical Stimulation Training After Spinal Cord Injury
Published on: February 1, 2018
Acute motor weakness of opposite lower extremity after percutaneous epidural neuroplasty
Yong Seok Lim1, Ki Tea Jung2, Cheon Hee Park1
1Department of Anesthesiology and Pain Medicine, Kwangju Christian Hospital, Gwangju, Korea.
Abstract:
Recently, percutaneous epidural neuroplasty has become widely used to treat radicular pain caused by spinal stenosis or a herniated intervertebral disc. A 19-year-old female patient suffering from left radicular pain caused by an L4-L5 intervertebral disc herniation underwent percutaneous epidural neuroplasty of the left L5 nerve root using a Racz catheter. After the procedure, the patient complained of acute motor weakness in the right lower leg, on the opposite site to where the neuroplasty was conducted. Emergency surgery was performed, and swelling of the right L5 nerve root was discovered. The patient recovered her motor and sensory functions immediately after the surgery. Theoretically, the injection of a large volume of fluid in a patient with severe spinal stenosis during epidural neuroplasty can increase the pressure on the opposite side of the epidural space, which may cause injury of the opposite nerve by barotrauma from a closed compartment. Practitioners should be aware of this potential complication.
Related Concept Videos
Peripheral Arterial Disease II: Clinical Manifestations and Diagnostic Evaluation
Peripheral Artery Disease V: Postoperative Nursing Management
Local Anesthetics: Clinical Application as Epidural Anesthesia
Since epidural anesthetics can be infused through an epidural catheter, all types of drugs, including short-acting ones, can be administered. Chloroprocaine and lidocaine are examples of short and long-duration anesthetics, respectively. Bupivacaine...