Related Experiment Video
Updated: Apr 15, 2026

In Vitro Application of a Wireless Sensor in Flexion-Extension Gap Balance of Unicompartmental Knee Arthroplasty
Published on: May 5, 2023
[Kinematic alignment in total knee arthroplasty : Concept, evidence base and limitations]
T Calliess1, M Ettinger, C Stukenborg-Colsmann
1Department Endoprothetik und Rekonstruktive Gelenkchirurgie, Orthopädische Klinik der Medizinischen Hochschule Hannover im Annastift, Anna-von-Borries-Str. 3, 30449, Hannover, Deutschland, Tilman.Calliess@ddh-gruppe.de.
Background:
Against the background that 20 % of patients are dissatisfied after total knee arthroplasty, there is ongoing controversy about optimal alignment. In this context, orientating the prosthetic components to the natural kinematic axes of the knee appears to be an interesting new concept.
Methods:
The objective of this paper is to provide a critical review of the current literature and our own research data regarding the concept of kinematically aligned total knee arthroplasty with the current evidence base and potential limitations.
Results And Discussion:
In the recent literature faster rehabilitation, better knee function, and higher patient satisfaction are described compared to conventional alignment, even if the postoperative alignment deviates more than 3° from the mechanical axis. However, the technique may not be suitable for every patient and pathology, and further research is necessary to set the correct indication.