Related Experiment Video
Updated: Apr 15, 2026

A Pre-Clinical Porcine Model of Orthotopic Heart Transplantation
Published on: April 27, 2019
Determinants of peak VO2 in heart transplant recipients
Vitor Oliveira Carvalho1, Guilherme Veiga Guimarães1, Marcelo Luiz Campos Vieira
1Hospital das Clínicas, Faculdade de Medicina, USP, São Paulo, Brazil.
Objective:
To establish the determinants of the peak VO2 in heart transplant recipients.
Methods:
Patient's assessment was performed in two consecutive days. In the first day, patients performed the heart rate variability assessment followed by a cardiopulmonary exercise test. In the second day, patients performed a resting echocardiography. Heart transplant recipients were eligible if they were in a stable condition and without any evidence of tissue rejection diagnosed by endomyocardial biopsy. Patients with pacemaker, noncardiovascular functional limitations such as osteoarthritis and chronic obstructive pulmonary disease were excluded from this study.
Results:
Sixty patients (68% male, 48 years and 64 months following heart transplantation) were assessed. Multivariate analysis selected the following variables: receptor's gender (P=0.001), receptor age (P=0.049), receptor Body Mass Index (P=0.005), heart rate reserve (P <0.0001), left atrium diameter (P=0.016). Multivariate analysis showed r=0.77 and r2=0.6 with P <0.001. Equation: peakVO2=32.851 - 3.708 (receptor gender) - 0.067 (receptor age) - 0.318 (receptor BMI) + 0.145 (heart rate reserve) - 0.111 (left atrium diameter).
Conclusion:
The determinants of the peak VO2 in heart transplant recipients were: receptor sex, age, Body Mass Index, heart rate reserve and left atrium diameter. Heart rate reserve was the unique variable positively associated with peak VO2. This data suggest the importance of the sympathetic reinnervation in peak VO2 in heart transplant recipients.
Related Concept Videos
Cardiac Output I:Effect of Heart Rate on Cardiac Output
Cardiac output (CO) refers to the total amount of blood ejected by one of the ventricles in liters per minute (L/min). In a resting adult, CO ranges from 5 to 6 L/min, adjusting according to the body's metabolic requirements.
Effect of Heart Rate on Cardiac Output
Cardiac output adapts to metabolic demands during stress, physical activity, or illness. The autonomic nervous system regulates heart rate via the sinoatrial node. The parasympathetic nervous system decreases heart...
Kidney Transplant I: Introduction
Cardiac Output II: Effect of Stroke Volume on Cardiac Output
Preload
Preload refers to the initial elongation of the cardiac myocytes before contraction and is related to the volume of blood filling the heart at the end of diastole, or end-diastolic volume. The...
Exercise and Cardiac Output
Sustained exercise increases the muscles' oxygen demand, which can be...