(90)Y-PET/CT Imaging Quantification for Dosimetry in Peptide Receptor Radionuclide Therapy: Analysis and Corrections
Cinzia Fabbri1,2, Mirco Bartolomei3, Vincenzo Mattone3
11 Physics and Biomedical Technologies Unit, Bufalini Hospital , AUSL della Romagna, Cesena, Italy .
Purpose:
We evaluated the possibility to assess (90)Y-PET/CT imaging quantification for dosimetry in (90)Y-peptide receptor radionuclide therapy.
Methods:
Tests were performed by Discovery 710 Elite (GE) PET/CT equipment. A body-phantom containing radioactive-coplanar-spheres was filled with (90)Y water solution to reproduce different signal-to-background-activity-ratios (S/N). We studied minimum detectable activity (MDA) concentration, contrast-to-noise ratio (CNR), and full-width-at-half-maximum (FWHM). Subsequently, three recovery coefficients (RC)-based correction approaches were evaluated: maximum-RC, resolution-RC, and isovolume-RC. The analysis of the volume segmentation thresholding method was also assessed to derive a relationship between the true volume of the targets and the threshold to be applied to the PET images. (90)Y-PET/CT imaging quantification was then achieved on some patients and related with preclinical tests. Moreover, the dosimetric evaluation was obtained on the target regions.
Results:
CNR value was greater than 5 if the MDA was greater than 0.2 MBq/mL with no background activity and 0.5-0.7 MBq/mL with S/N ranging from 3 to 6. FWHM was equal to 7 mm. An exponential fitting of isovolume RCs-based correction technique was adopted for activity quantification. Adaptive segmentation thresholding exponential curves were obtained and applied for target volume identification in three signal-to-background-activity-ratios. The imaging quantification study and dosimetric evaluations in clinical cases was feasible and the results were coherent with those obtained in preclinical tests.
Conclusions:
(90)Y-PET/CT imaging quantification is possible both in phantoms and in patients. Absorbed dose evaluations in clinical applications are strongly related to targets activity concentration.
More Related Videos
09:55Radiosynthesis, Quality Control, and Small Animal Positron Emission Tomography Imaging of 68Ga-Labelled Nano Molecules
Published on: October 4, 2024
07:57Positron Emission Tomography-based Dose Painting Radiation Therapy in a Glioblastoma Rat Model using the Small Animal Radiation Research Platform
Published on: March 24, 2022
Related Concept Videos
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...