A Method for Tracking the Time Evolution of Steady-State Evoked Potentials
Published on: May 25, 2019
A setup for simultaneous measurement of electrophysiological and psychometric temporal encoding in the auditory
1University of Würzburg, Clinic for Otolaryngology, Comprehensive Hearing Center, 97080 Würzburg, Germany.
Background:
Simultaneous assessment of psychometric tasks and electrophysiological recordings is challenging because each requires specific technical and physiological preconditions. Electrophysiological recordings require a comparatively long test time duration to gain sufficient signal-to-noise ratios, whereas test duration of psychometric measurements should be limited to prevent challenges to the attention of the subject. In order to investigate immediate correlation between both measurements a method is described, which combines electrophysiological and psychometrical measurements in a single test procedure. The test may be applied to subjects with deficits in temporal resolution (e.g. auditory neuropathy spectrum disorder, ANSD).
New Method:
Auditory steady state responses (ASSR) and a pitch discrimination task were combined in a single procedure. The setup employed two short-time ASSR sub-stimuli with different fixed modulation frequencies but same carrier frequencies (signal 1 and 2). Simultaneously to the recording of ASSR, the test subject had to determine the signal interval which generated the perception of higher pitch.
Results:
The developed setup was successfully tested by means of an artificial EEG signal and in one human subject. ASSR signal as well as pitch discrimination performance.
Comparison With Existing Methods:
To our knowledge the presented method has not yet been described elsewhere.
Conclusions:
The feasibility of a setup to simultaneously perform a pitch discrimination task and electrophysiological measurements was demonstrated for the first time. The method provides the facility to apply sinusoidal amplitude modulated stimuli (SAM) with jittered modulation period lengths.