Related Experiment Video
Updated: Apr 15, 2026

Author Spotlight: Integrating High-Resolution Intravital Imaging and MRI to Enhance Stereotactic Body Radiation Therapy Planning
Published on: April 12, 2024
Simultaneous evaluation of vascular morphology, blood volume and transvascular permeability using SPION-based,
Heon-Ju Kwon1,2, Woo Hyun Shim1, Gyunggoo Cho3
1Department of Radiology, Research Institute of Radiology, Asan Medical Center, University of Ulsan College of Medicine, Asan Institute for Life Sciences, Seoul, South Korea.
Abstract:
Exploiting ultrashort-T(E) (UTE) MRI, T1-weighted positive contrast can be obtained from superparamagnetic iron oxide nanoparticles (SPIONs), which are widely used as a robust T2-weighted, negative contrast agent on conventional MR images. Our study was designed (a) to optimize the dual-contrast MRI method using SPIONs and (b) to validate the feasibility of simultaneously evaluating the vascular morphology, blood volume and transvascular permeability using the dual-contrast effect of SPIONs. All studies were conducted using 3 T MRI. According to numerical simulation, 0.15 mM was the optimal blood SPION concentration for visualizing the positive contrast effect using UTE MRI (T(E) = 0.09 ms), and a flip angle of 40° could provide sufficient SPION-induced enhancement and acceptable measurement noise for UTE MR angiography. A pharmacokinetic study showed that this concentration can be steadily maintained from 30 to 360 min after the injection of 29 mg/kg of SPIONs. An in vivo study using these settings displayed image quality and CNR of SPION-enhanced UTE MR angiography (image quality score 3.5; CNR 146) comparable to those of the conventional, Gd-enhanced method (image quality score 3.8; CNR 148) (p > 0.05). Using dual-contrast MR images obtained from SPION-enhanced UTE and conventional spin- and gradient-echo methods, the transvascular permeability (water exchange index 1.76-1.77), cerebral blood volume (2.58-2.60%) and vessel caliber index (3.06-3.10) could be consistently quantified (coefficient of variation less than 9.6%; Bland-Altman 95% limits of agreement 0.886-1.111) and were similar to the literature values. Therefore, using the optimized setting of combined SPION-based MRI techniques, the vascular morphology, blood volume and transvascular permeability can be comprehensively evaluated during a single session of MR examination.
Related Concept Videos
Magnetic Resonance Imaging
Imaging Studies VII: Vascular Imaging
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this...
Imaging Studies for Cardiovascular System IV: CMRI
Venous Thrombosis II: Clinical Manifestations and Diagnostic Studies