Utilizing Percutaneous Ventricular Assist Devices in Acute Myocardial Infarction Complicated by Cardiogenic Shock
Published on: June 12, 2021
Implementing an Innovative Cardiac Assist System in a Nonuniversity Hospital--Feasibility, Complications, and First
Jochen Graf1, Wolfram Radunz1, Isabell Häger1
1SLK-Kliniken Heilbronn GmbH, Klinikum Am Gesundbrunnen, Medical Department I, Heilbronn, Germany.
Abstract:
To evaluate the feasibility of implementing a cardiac assist system in a nonuniversity hospital we analyzed 18 consecutive patients treated with venoarterial membrane oxygenation. The system was used electively in 5/18 (27.8%) patients during high-risk interventions. Thirteen patients (72.2%) were treated in emergency situations. The extracorporal system could be initiated successfully in all patients. Periprocedural complications were hemolysis in 3/18 (16.7%), disseminated intravascular coagulation in 2/18 (11.1%), cerebral ischemia in 1/18 (5.6%), and local infection in 2/18 (11.1%) patients. None of these led to a discontinuation of the therapy. All electively treated patients were successfully weaned from the extracorporeal system. In 9/13 (69.2%) emergency patients the system was removed successfully. The 60-day survival rate of the emergency patients was 53.8% (7/13). Our experience confirms that an innovative extracorporeal circulatory support system can be implemented in a nonuniversity hospital at a tolerable risk and a low complication and high procedural success rate.