Interaction-free measurements by quantum Zeno stabilization of ultracold atoms

J Peise1, B Lücke1, L Pezzé2

  • 1Institut für Quantenoptik, Leibniz Universität Hannover, Welfengarten 1, D-30167 Hannover, Germany.

Nature Communications
|April 15, 2015
PubMed

Related Concept Videos

Atomic Nuclei: Nuclear Relaxation Processes01:23

Atomic Nuclei: Nuclear Relaxation Processes

In the absence of an external magnetic field, nuclear spin states are degenerate and randomly oriented. When a magnetic field is applied, the spins begin to precess and orient themselves along (lower energy) or against (higher energy) the direction of the field. At equilibrium, a slight excess population of spins exists in the lower energy state. Because the direction of the magnetic field is fixed as the z-axis,  the precessing magnetic moments are randomly oriented around the z-axis.
1.4K
Atomic Force Microscopy01:08

Atomic Force Microscopy

Atomic force microscopy (AFM) is a type of scanning probe microscopy that can analyze topographic details of various specimens like ceramics, glass, polymers, and biological samples. AFM offers over 1000 times more resolution than the optical imaging system. Images generated from AFM are three-dimensional surface profiles, offering an advantage over the flat, two-dimensional images from other imaging techniques.
The AFM Probe
The probe is regarded as the heart of any AFM setup and comprises the...
4.8K
The Quantum-Mechanical Model of an Atom02:45

The Quantum-Mechanical Model of an Atom

Shortly after de Broglie published his ideas that the electron in a hydrogen atom could be better thought of as being a circular standing wave instead of a particle moving in quantized circular orbits, Erwin Schrödinger extended de Broglie’s work by deriving what is now known as the Schrödinger equation. When Schrödinger applied his equation to hydrogen-like atoms, he was able to reproduce Bohr’s expression for the energy and, thus, the Rydberg formula governing...
62.0K
Atomic Absorption Spectroscopy: Atomization Methods01:25

Atomic Absorption Spectroscopy: Atomization Methods

Atomic Absorption Spectroscopy (AAS) atomizes samples through flame atomization or electrothermal atomization. Flame atomization typically involves a nebulizer and spray chamber assembly to combine the sample with a fuel–oxidant mixture, creating a fine aerosol mist that enters a burner. Typically, the fuel and oxidant are combined in an approximately stoichiometric ratio. However, for atoms that are easily oxidized, a fuel-rich mixture may be more advantageous. Only about 5% of the...
2.0K