Blood pressure and adverse events during continuous flow left ventricular assist device support
Omar Saeed1, Rita Jermyn1, Faraj Kargoli1
1From the Division of Cardiology, Department of Medicine (O.S., R.J., F.K., S.M., S.M., S.G., C.N., R.Z., J.S., S.R.P.) and Department of Cardiothoracic Surgery (D.D'A., D.J.G.), Montefiore Medical Center, Albert Einstein College of Medicine, Bronx, NY; and Division of Cardiology, Department of Medicine (S.F., S.H., M.B.) and Division of Cardiothoracic Surgery, Department of Surgery (A.M.), Stony Brook University, Long Island, NY.
Background:
Adverse events (AEs), such as intracranial hemorrhage, thromboembolic event, and progressive aortic insufficiency, create substantial morbidity and mortality during continuous flow left ventricular assist device support yet their relation to blood pressure control is underexplored.
Methods And Results:
A multicenter retrospective review of patients supported for at least 30 days and ≤18 months by a continuous flow left ventricular assist device from June 2006 to December 2013 was conducted. All outpatient Doppler blood pressure (DOPBP) recordings were averaged up to the time of intracranial hemorrhage, thromboembolic event, or progressive aortic insufficiency. DOPBP was analyzed as a categorical variable grouped as high (>90 mm Hg; n=40), intermediate (80-90 mm Hg; n=52), and controlled (<80 mm Hg; n=31). Cumulative survival free from an AE was calculated using Kaplan-Meier curves and Cox hazard ratios were derived. Patients in the high DOPBP group had worse baseline renal function, lower angiotensin-converting enzyme inhibitor or angiotensin receptor blocker usage during continuous flow left ventricular assist device support, and a more prevalent history of hypertension. Twelve (30%) patients in the high DOPBP group had an AE, in comparison with 7 (13%) patients in the intermediate DOPBP group and only 1 (3%) in the controlled DOPBP group. The likelihood of an AE increased in patients with a high DOPBP (adjusted hazard ratios [95% confidence interval], 16.4 [1.8-147.3]; P=0.012 versus controlled and 2.6 [0.93-7.4]; P=0.068 versus intermediate). Overall, a similar association was noted for the risk of intracranial hemorrhage (P=0.015) and progressive aortic insufficiency (P=0.078) but not for thromboembolic event (P=0.638). Patients with an AE had a higher DOPBP (90±10 mm Hg) in comparison with those without an AE (85±10 mm Hg; P=0.05).
Conclusions:
In a population at risk, higher DOPBP during continuous flow left ventricular assist device support was significantly associated with a composite of AEs.
More Related Videos
Related Concept Videos
Measurement of Blood Pressure
Heart Failure VI: Adjunct Therapies
Heart Failure II: Pathophysiology
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Heart Failure V: Medical Management
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.