Related Experiment Video
Updated: Apr 14, 2026

Multimodality Diagnosis of Mesenteric Ischemia
Published on: July 21, 2023
Usefulness of intraoperative observation using a fluorescence imaging instrument for patients with nonocclusive
Mitsuru Ishizuka1, Hitoshi Nagata, Kazutoshi Takagi
11 Department of Gastroenterological Surgery and.
Abstract:
The authors evaluated the usefulness of intraoperative photodynamic eye (PDE) observation in patients with nonocclusive mesenteric ischemia (NOMI). Between February 2012 and July 2013, 6 patients who had undergone emergency surgery for NOMI were enrolled. Intraoperative PDE observation was performed to decide the adequate length of bowel resection including all skipped dark spots, which could not be detected as ongoing mucosal ischemic changes under visible light observation. All ongoing mucosal ischemic changes were easily detected as dark spots using PDE observation in all 6 patients. The mean length of adequate ileal resection (92 ± 48 cm) was significantly longer than that of ischemic ileum (85 ± 50 cm) (mean ± SD) (P = 0.043). After resection of an adequate length of bowel, all the patients had a good course until discharge without incidents due to residual bowel ischemia, except for 1patient who died. PDE observation is useful for deciding the adequate length of bowel to resect, including ongoing mucosal ischemic changes that cannot be detected under visible light observation. In patients with NOMI, resection of an adequate length of bowel is necessary to prevent postoperative incidents due to residual bowel ischemia.