Insertion, Maintenance, and Removal of the Percutaneous Dual Lumen Cannula Right Ventricular Assist Device
Published on: July 20, 2022
Right ventricular assist device with membrane oxygenator support for right ventricular failure following implantable
Jeremy Leidenfrost1, Sunil Prasad1, Akinobu Itoh2
1Division of Cardiothoracic Surgery, Department of Surgery, Washington University School of Medicine, Saint Louis, MO, USA.
Objectives:
Cardiogenic shock from refractory right ventricular (RV) failure during left ventricular assist device placement is associated with high morbidity and mortality. The addition of extracorporeal membrane oxygenation to RV mechanical assistance may help RV recovery and lead to improved outcomes.
Methods:
We retrospectively reviewed all implanted continuous-flow left ventricular assist devices from April 2009 to June 2013. RV mechanical support was utilized for RV failure defined as haemodynamic instability despite vasopressors, pulmonary vascular dilators and inotropic therapy. RV assist devices were utilized with and without in-line membrane oxygenation.
Results:
During the study period, 267 continuous-flow left ventricular assist devices were implanted. RV mechanical support was utilized in 27 (10%) patients; 12 (46%) had the addition of in-line extracorporeal membrane oxygenation. The mean age of patients with a right ventricular assist device with membrane oxygenation was lower than that in patients with a right ventricular assist device alone (45.6 ± 15.9 vs 64.6 ± 6.5, P = 0.001). Support was weaned in 66% (10 of 15) of patients with right ventricular assist device (RVAD) alone vs 83% (10 of 12) of those with RVAD with membrane oxygenation (P = 0.42). The RVAD was removed after 10.4 ± 9.4 vs 5 ± 2.99 days for patients with a RVAD with membrane oxygenation (P = 0.1). Patients with RVAD with membrane oxygenation had a 30-day mortality rate of 8 vs 47% for those with RVAD alone (P = 0.04). The survival rate after discharge was 86, 63 and 54% at 3, 6 and 12 months for both groups combined.
Conclusions:
Patients with a RVAD with membrane oxygenation support for acute RV failure after continuous-flow left ventricular assist device implantation had a lower 30-day mortality than those with a RVAD alone. Patients who survive to discharge have a reasonable 1-year survival. Combining membrane oxygenation with RVAD support appears to offer a short-term survival benefit in patients with RV failure after continuous-flow left ventricular assist device implantation.
Related Concept Videos
Cardiomyopathy V: Interprofessional Care
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Ventilatory Modes
There are three ventilatory modes: full support, partial support, and spontaneous. These are described below.
Full Support Modes
Full support modes include controlled mechanical ventilation, continuous mandatory...
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
Acute Respiratory Failure-V
Ensure that patients are monitored continuously for their response to therapy, including changes in...
Cardiopulmonary Resuscitation II: ACLS Airway Management