Related Experiment Video
Updated: Apr 14, 2026

Measuring the Carotid to Femoral Pulse Wave Velocity Cf-PWV to Evaluate Arterial Stiffness
Published on: May 3, 2018
Uneven Accuracy of Home Blood Pressure Measurement: A Multicentric Survey
Maria Elena Flacco1,2, Lamberto Manzoli1,2,3,4, Marco Bucci1,3
1Department of Medicine and Aging Sciences, University of Chieti, Chieti, Italy.
Insights
Most patients performing home blood pressure monitoring (HBPM) do not follow recommended techniques, impacting accuracy. Providing patient training on HBPM significantly improves measurement quality.
Area of Science:
- Cardiovascular Medicine
- Hypertension Management
- Patient Education
Background:
- Home blood pressure monitoring (HBPM) is widely used but its accuracy is questionable due to poor patient technique.
- Limited data exists on patient adherence to recommended HBPM practices.
Purpose of the Study:
- To assess patient adherence to HBPM recommendations.
- To identify factors predicting higher-quality self-measurement of blood pressure.
Main Methods:
- A multicentric survey using a structured questionnaire.
- 725 Italian hypertensive outpatients participated.
- Analysis of adherence to ≥10 recommended HBPM procedures.
Main Results:
- Only 1.0% of patients followed all recommendations; 52.8% followed ≥10 procedures.
- Key adherence gaps included pre-measurement rest (49.7%), repeated measurements (36.8%), and proper posture (34.3%).
- Patients receiving/reading instructions demonstrated significantly higher HBPM quality (P<.01).
Conclusions:
- The accuracy of home blood pressure monitoring requires improvement.
- Enhanced patient training on HBPM techniques is crucial, particularly for less-followed recommendations.
Abstract:
Home blood pressure monitoring (HBPM) is increasingly commonly performed, but the concordance between patient HBPM measurement technique and prevailing recommendations has not been well-assessed according to the literature. The authors performed a multicentric survey to evaluate the degree of patients' adherence to current recommendations on HBPM, and investigate potential predictors of a higher-quality self-measurement. A structured questionnaire was administered to 725 Italian outpatient hypertensive patients (mean age, 52.2±14.4 years). Overall, ≥10 recommended procedures were followed by 52.8% of the participants; only 1.0% followed all recommendations. A total of 49.7% of participants rested for ≥5 minutes before the measurement, 36.8% recorded BP more than once in each measurement session, and 34.3% used a chair or bed saddle to support their back. Less than 40% of the patients received some form of training by health professionals. After multivariate analysis, patients receiving/reading instructions showed higher-quality HBPM (P<.01). The accuracy of HBPM needs to be improved, and more efforts should be devoted to provide patient training on HBPM, especially on the less-frequently followed recommendations.
More Related Videos
07:35Simultaneous Electrocardiography Recording and Invasive Blood Pressure Measurement in Rats
Published on: January 31, 2019
05:51Assessing the Accuracy of Fitness Smartwatch Data for Cardiovascular and Physical Activity Monitoring: A Validation Study in Digital Health
Published on: February 21, 2025
Related Concept Videos
Errors occurring during blood pressure monitoring
Several factors...
Pre-Procedural Guidelines for Assessing Blood Pressure
Sites for measuring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Assessment of blood pressure in brachial artery(two-step method)
Measurement of Blood Pressure