Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Weir01:24

Weir

675
A weir is a hydraulic structure designed to partially obstruct an open channel, enabling precise control and measurement of water flow. By forcing water to flow over or through it, a weir allows for accurate determination of discharge rates, making it an essential tool in water resource management. These structures are extensively used in regulating river flows, irrigation systems, and flood control channels.Types of Weirs and Their FeaturesWeirs are categorized primarily into sharp-crested and...
675
Underflow Gates01:30

Underflow Gates

541
Underflow gates are vital for controlling water flow in irrigation canals. The three main types of underflow gates — vertical, radial, and drum gates — serve different purposes while ensuring effective flow management. Vertical gates move up and down, generating a free-flowing water jet; radial gates pivot to regulate the flow; and drum gates rotate for precise adjustments. The flow through these gates is influenced by downstream conditions, resulting in free or drowned outflow.Free and...
541
Weir: Problem Solving01:26

Weir: Problem Solving

803
Water flow in open channels is often measured using hydraulic structures such as weirs, which allow precise calculation of discharge. In a rectangular channel, flow rates are measured using three types of weirs: rectangular sharp-crested, triangular sharp-crested, and broad-crested. The weir head is set at a fixed height above the channel bottom, simplifying calculations and enabling the relationship between depth and flow rate to be analyzed.For the rectangular sharp-crested weir, the flow...
803
Testing Water Quality01:14

Testing Water Quality

585
When the quality of water for concrete preparation is uncertain, its impact on the setting time of cement and compressive strength of mortar is assessed by comparison with de-ionized or distilled water benchmarks. American Society for Testing and Materials (ASTM) C1602 requires the setting times to be within 90 minutes of the control, British Standard (BS) 3146:1980 allows a 30-minute variance in the initial setting, while British Standards European Norm (BS EN) 1008 specifies initial setting...
585
Regulation of Water Output01:26

Regulation of Water Output

2.6K
The human body predominantly expels water through the urinary system. On average, an individual generates around 1.5 liters of urine each day. This amount can fluctuate based on how well a person is hydrated, but a critical minimum quantity of urine must be produced to ensure the body's proper functioning. Daily, the kidneys remove 600 to 1200 milliosmoles of dissolved substances, effectively excreting excess minerals and water-soluble toxins such as creatinine, urea, and uric acid from the...
2.6K
Quality of Water01:19

Quality of Water

721
In concrete preparation, the quality of water is paramount as it affects the strength and durability of the concrete. Potable water is usually preferred; however, it must not have excessive sodium or potassium to prevent compromising the concrete's integrity. Water quality is typically evaluated based on impurities such as dissolved solids, chlorides, and sulfates, and its pH value is ideally between 6 and 8. Even slightly acidic natural water may be acceptable unless it contains harmful...
721

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Role of soluble guanylyl cyclase in renal afferent and efferent arterioles.

American journal of physiology. Renal physiology·2020
Same author

[Contrast medium-induced acute kidney injury-Consensus paper of the working group "Heart and Kidney" of the German Cardiac Society and the German Society of Nephrology].

Der Internist·2020
Same author

A dual role of miR-22 in rhabdomyolysis-induced acute kidney injury.

Acta physiologica (Oxford, England)·2018
Same author

Dissociation between the pharmacokinetics and pharmacodynamics of once-daily rivaroxaban and twice-daily apixaban: a randomized crossover study.

Journal of thrombosis and haemostasis : JTH·2017
Same journal

Functional Differences in Electrolyte Transport Between the Mouse Proximal and Distal Trachea.

Acta physiologica (Oxford, England)·2026
Same journal

Myosin Post-Translational Modifications Associated With Critical Illness Myopathy.

Acta physiologica (Oxford, England)·2026
Same journal

Phenylalanine Versus Tyrosine (Pos. 367/332 in MCT1/MCT4) in the Substrate Binding Site Defines Affinity and Preferred Directionality of Human Monocarboxylate Transporters 1-4.

Acta physiologica (Oxford, England)·2026
Same journal

Aberrant Potassium Handling by Astrocytes and Epileptic Seizures: A Synthetic Update.

Acta physiologica (Oxford, England)·2026
Same journal

Thermoneutrality Reveals True Cardiac Adaptations to Exercise, Disease, and Aging in Male Mice.

Acta physiologica (Oxford, England)·2026
Same journal

Clustering Properties of Neuronal Ryanodine Receptor 2 and Remodeling in the APP/PS1 Mouse Model of Alzheimer's Disease.

Acta physiologica (Oxford, England)·2026
See all related articles

Related Experiment Video

Updated: Apr 14, 2026

Parameterizing V-notch Weir Equations for Flow Monitoring in a Drainage Control Structure
07:15

Parameterizing V-notch Weir Equations for Flow Monitoring in a Drainage Control Structure

Published on: April 25, 2025

1.3K

Waterworks

P B Persson1

  • 1Institute of Vegetative Physiology, Charité-Universitaetsmedizin Berlin, Berlin, Germany. pontus.persson@charite.de.

Acta Physiologica (Oxford, England)
|April 18, 2015
PubMed
Summary

No abstract available in PubMed .

More Related Videos

Vegetated Treatment Systems for Removing Contaminants Associated with Surface Water Toxicity in Agriculture and Urban Runoff
08:49

Vegetated Treatment Systems for Removing Contaminants Associated with Surface Water Toxicity in Agriculture and Urban Runoff

Published on: May 15, 2017

11.5K
Mesocosm-Scale Constructed Wetland Design for Wastewater Treatment
08:24

Mesocosm-Scale Constructed Wetland Design for Wastewater Treatment

Published on: May 2, 2025

1.2K

Related Experiment Videos

Last Updated: Apr 14, 2026

Parameterizing V-notch Weir Equations for Flow Monitoring in a Drainage Control Structure
07:15

Parameterizing V-notch Weir Equations for Flow Monitoring in a Drainage Control Structure

Published on: April 25, 2025

1.3K
Vegetated Treatment Systems for Removing Contaminants Associated with Surface Water Toxicity in Agriculture and Urban Runoff
08:49

Vegetated Treatment Systems for Removing Contaminants Associated with Surface Water Toxicity in Agriculture and Urban Runoff

Published on: May 15, 2017

11.5K
Mesocosm-Scale Constructed Wetland Design for Wastewater Treatment
08:24

Mesocosm-Scale Constructed Wetland Design for Wastewater Treatment

Published on: May 2, 2025

1.2K