Related Experiment Video
Updated: Apr 14, 2026

Tracking the Mammary Architectural Features and Detecting Breast Cancer with Magnetic Resonance Diffusion Tensor Imaging
Published on: December 15, 2014
3D-MR Ductography and Contrast-Enhanced MR Mammography in Patients with Suspicious Nipple Discharge; a Feasibility
Brandi T Nicholson1, Jennifer A Harvey1, James T Patrie2
1Department of Radiology & Medical Imaging, University of Virginia, Charlottesville, Virginia.
Abstract:
We evaluated contrast-enhanced magnetic resonance (ce-MR) imaging and an indirect MR galactogram (MRG) sequence against conventional galactography (CG) in women with suspicious nipple discharge who underwent histologic diagnosis. This study was Institutional Review Board approved and HIPAA compliant. Women with suspicious nipple discharge recommended for CG were recruited for our study. Patients underwent both a ce-MR as well as MRG (MRG-1 and MRG-2, variations in isotropic spatial resolution) followed by CG within 60 days. The ce-MR and MRG studies were interpreted together by a single radiologist separately from CG. Pathology was used as our gold standard and was obtained via image-guided core needle biopsy or surgery with papilloma, atypia, and malignancy considered positive. Of the 21 patients recruited for the study, 20 patients had known histology results for 26 lesions; 18 patients (90.0%) had successful CG, 20 (100.0%) ce-MRI, 20 (100.0%) MRG-1, and 19 (95.0%) MRG-2. Histology showed 5 cancers (4 women), 15 papillomas (2 with atypia) (11 women), and 6 additional benign lesions (6 women). Five patients (25.0%) had additional lesions detected by ce-MR that influenced surgical management. Sensitivity, specificity, positive (PPV), and negative predicted values (NPV) for CG, ce-MRI, MRG-1 were 65.0, 33.3, 76.5, and 22.2; 95.0, 66.7, 90.5, and 80.8; 55.0, 66.7, 84.6, and 30.8, respectively. ce-MR had the highest sensitivity, PPV, and NPV compared with CG or MRG. Our MRG protocols show promise, but were not as sensitive as ce-MRI for women with suspicious nipple discharge.
Related Concept Videos
Magnetic Resonance Imaging
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Radiological Investigation II: MRI and Ventilation Perfusion Scan
Magnetic Resonance Imaging (MRI) and Ventilation Perfusion Scans are two radiological investigations that offer detailed diagnostic images of the body, particularly lung structures.
MRI
MRI uses magnetic fields and radiofrequency signals to distinguish between normal and abnormal tissues. This technology provides a more detailed diagnostic image than CT scans, enabling it to characterize pulmonary nodules, stage bronchogenic carcinoma, and evaluate inflammatory activity in...
Imaging Studies IV: Magnetic Resonance Imaging
Imaging Studies for Cardiovascular System IV: CMRI
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...