Multicenter validation of a shortened gastric-emptying protocol
Matthieu Pelletier-Galarneau1, Oyebola O Sogbein2, Xuan Pham2
1The Ottawa Hospital, Division of Nuclear Medicine, Ottawa, Ontario, Canada mattgalarneau@gmail.com.
Unlabelled:
Gastric emptying scintigraphy is considered to be the gold standard for detection of gastroparesis and other disorders of gastric motility; Society of Nuclear Medicine and Molecular Imaging guidelines are predicated on imaging over a period of 4 h, which is inconvenient for patients. Bonta et al. introduced 2-h criteria, which served to shorten the protocol in most patients, with negligible loss of accuracy. We have evaluated the Bonta criteria in a larger multicenter trial encompassing 4 academic institutions.
Methods:
Retrospective data from 4 academic medical centers were aggregated; 431 patients were included, 105 (24.4%) of whom demonstrated delayed gastric emptying defined by 4-h gastric retention of more than 10%. Bonta criteria (retention > 65% is considered abnormal and < 45% normal; otherwise, proceed to complete examination) were applied to the 2-h data. Sensitivity, specificity, accuracy, and resource use for the Bonta method were calculated. Results based on standard 4-h solid gastric emptying, performed according to current Society of Nuclear Medicine and Molecular Imaging guidelines, served as the gold standard.
Results:
Retention of 10% or less was achieved by 6, 77, 215, and 326 patients at 1, 2, 3, and 4 h, respectively. At 2 h, 261 of 431 patients (60.6%) had gastric retention of less than 45%, which according to Bonta would be classified as normal; 62 (14.4%) had gastric retention of more than 65%, which would be classified as delayed emptying; and 108 (25.1%) had intermediate values requiring further imaging through 4 h. The Bonta criteria yielded a sensitivity, specificity, and accuracy of 92.4%, 96.9%, and 95.8%, respectively, superior to any single cutoff point applied to the 2-h values. The criteria resulted in false-negative results in 8 (1.9%) patients, 6 of whom were borderline-positive at 4 h (gastric retention of 11%-14%). Using the Bonta criteria, 74.9% of studies would be terminated by 2 h, decreasing total camera use by 15.7%, from 1,768 to 1,490 images, and the average study duration would be reduced by 20.6%, from 3.1 to 2.5 h.
Conclusion:
In a multicenter cohort, use of the Bonta criteria shortened the duration of studies in most patients, resulting in an effective compromise between reduced resource use, improved patient convenience, and preserved accuracy.
More Related Videos
12:24Assessment of Gastric Emptying in Non-obese Diabetic Mice Using a [13C]-octanoic Acid Breath Test
Published on: March 23, 2013
04:53A Clinical Trial Assessing the Safety, Efficacy, and Delivery of Olive-Oil-Based Three-Chamber Bags for Parenteral Nutrition
Published on: September 20, 2019
Related Concept Videos
Gastric Emptying
Imaging Studies III: Gastrointestinal Motility Studies and Virtual Colonoscopy
Radionuclide Testing
Radionuclide testing is a sophisticated medical technique for assessing gastrointestinal motility. It focuses on gastric emptying and colonic transit time. Radioactive markers track the movement of food through the digestive system, providing insights into gastrointestinal disorders.
In gastric emptying studies, a meal's liquid and...
One-Compartment Open Model for IV Bolus Administration: Estimation of Clearance
In the one-compartment open model for intravenous (IV) bolus administration, clearance is estimated by dividing the elimination rate by the plasma drug concentration. This equation leverages the elimination rate constant and the apparent...