Background:
The objective of this study was to evaluate the feasibility and diagnostic value of 18F-fluorodeoxyglucose positron emission tomography/computed tomography (18F-FDG PET/CT) and (99m)Tc-methylenediphosphonate (MDP) whole-body bone scanning (BS) for the detection of osteolytic bone metastases.
Methods:
Thirty-four patients with pathologically confirmed malignancies and suspected osteolytic bone metastases underwent 18F-FDG PET/CT and (99m)Tc-MDP whole-body BS within 30 days. The sensitivity, specificity, and accuracy with respect to the diagnosis of osteolytic bone metastases and bone lesions were compared between the two imaging methods.
Results:
The sensitivity, specificity, and accuracy of 18F-FDG PET/CT for the diagnosis of osteolytic bone metastases were 94.3% (95% confidence interval [CI], 91.6-96.2%), 83.3% (95% CI, 43.6-96.9%), and 94.2% (95% CI, 91.5-96.1%), respectively. It was found that (99m)Tc-MDP whole-body BS could discriminate between patients with 50.2% (95% CI, 45.4-55.1%) sensitivity, 50.0% (95% CI, 18.8-81.2%) specificity, and 50.2% (95% CI, 45.5-55.1%) accuracy. 18F-FDG PET/CT achieved higher sensitivity, specificity, and accuracy in detecting osteolytic bone metastases than 99mTc-MDP whole-body BS (p<0.001).
Conclusions:
F-FDG PET/CT has a higher diagnostic value than (99m)Tc-MDP whole-body BS in the detection of osteolytic bone metastases, especially in the vertebra.
More Related Videos
12:23Multi-modal Imaging of Angiogenesis in a Nude Rat Model of Breast Cancer Bone Metastasis Using Magnetic Resonance Imaging, Volumetric Computed Tomography and Ultrasound
Published on: August 14, 2012
06:31Quantitative [18F]-Naf-PET-MRI Analysis for the Evaluation of Dynamic Bone Turnover in a Patient with Facetogenic Low Back Pain
Published on: August 8, 2019
Related Concept Videos
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...