Evaluating the Effects of Different Polishing Methods on Color Stability of Dental Restorations in Pediatric Dentistry
Published on: June 6, 2025
Color difference thresholds in dentistry
Rade D Paravina1, Razvan Ghinea, Luis J Herrera
1Department of Restorative Dentistry and Prosthodontics, School of Dentistry, University of Texas, Houston, TX, USA; Houston Center for Biomaterials and Biomimetics (HCBB), Houston, TX, USA.
Purpose:
The aim of this prospective multicenter study was to determine 50:50% perceptibility threshold (PT) and 50:50% acceptability threshold (AT) of dental ceramic under simulated clinical settings.
Materials And Methods:
The spectral radiance of 63 monochromatic ceramic specimens was determined using a non-contact spectroradiometer. A total of 60 specimen pairs, divided into 3 sets of 20 specimen pairs (medium to light shades, medium to dark shades, and dark shades), were selected for psychophysical experiment. The coordinating center and seven research sites obtained the Institutional Review Board (IRB) approvals prior the beginning of the experiment. Each research site had 25 observers, divided into five groups of five observers: dentists-D, dental students-S, dental auxiliaries-A, dental technicians-T, and lay persons-L. There were 35 observers per group (five observers per group at each site ×7 sites), for a total of 175 observers. Visual color comparisons were performed using a viewing booth. Takagi-Sugeno-Kang (TSK) fuzzy approximation was used for fitting the data points. The 50:50% PT and 50:50% AT were determined in CIELAB and CIEDE2000. The t-test was used to evaluate the statistical significance in thresholds differences.
Results:
The CIELAB 50:50% PT was ΔEab = 1.2, whereas 50:50% AT was ΔEab = 2.7. Corresponding CIEDE2000 (ΔE00 ) values were 0.8 and 1.8, respectively. 50:50% PT by the observer group revealed differences among groups D, A, T, and L as compared with 50:50% PT for all observers. The 50:50% AT for all observers was statistically different than 50:50% AT in groups T and L.
Conclusion:
A 50:50% perceptibility and ATs were significantly different. The same is true for differences between two color difference formulas ΔE00 /ΔEab . Observer groups and sites showed high level of statistical difference in all thresholds.
Clinical Significance:
Visual color difference thresholds can serve as a quality control tool to guide the selection of esthetic dental materials, evaluate clinical performance, and interpret visual and instrumental findings in clinical dentistry, dental research, and subsequent standardization. The importance of quality control in dentistry is reinforced by increased esthetic demands of patients and dental professionals.
Related Concept Videos
Photoreceptors and Visual Pathways
Difference from Background: Limit of Detection
The LOD indicates the presence or absence...
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
Indicators
Differential Staining Technique
Color Vision