Related Experiment Video
Updated: Apr 14, 2026

Remote Magnetic Navigation for Accurate, Real-time Catheter Positioning and Ablation in Cardiac Electrophysiology Procedures
Published on: April 21, 2013
Dual atrioventricular nodal non-re-entrant tachycardia
Christiane Peiker1, Christian Pott2, Lars Eckardt2
1Department of Cardiology - Electrophysiology, University Heart Centre, University Hospital Hamburg-Eppendorf, Martinistrasse 52, D-20246, Hamburg, Germany DZHK (German Centre for Cardiovascular Research), Partner site Hamburg, Kiel, Lübeck, Germany Department of Cardiology, Pulmonology and Vascular Medicine, Medical Faculty, University Hospital Duesseldorf, Germany.
Abstract:
Dual atrioventricular nodal non-re-entrant tachycardia (DAVNNT), also known as 'double fire', has recently received more attention since it was demonstrated to mimic more common arrhythmias such as atrial premature beats, atrial fibrillation, and ventricular tachycardia. This is important, since mistaken differential diagnoses and the resulting therapeutic decisions have severe consequences for affected patients. DAVNNT is characterized by conduction characteristics of the atrioventricular (AV) node that leads to a double antegrade conduction of one sinoatrial nodal activity via the slow and fast AV nodal pathways. As a result, the most significant hint from an electrocardiogram (ECG) is a P wave followed by two narrow QRS complexes. Although DAVNNT is rather a rare arrhythmia, it now appears to be more common than previously thought. To date, 68 cases including 3 small single-centre observational studies accumulated over the last 5 years have demonstrated the feasibility and safety of radiofrequency catheter ablation for DAVNNT. Catheter ablation treats this arrhythmia effectively by modifying or eliminating slow pathway function. Here, we review the current state of DAVNNT knowledge systematically and address current challenges presented by this 'ECG chameleon from the AV node'.
More Related Videos
06:57Ablation of Ischemic Ventricular Tachycardia Using a Multipolar Catheter and 3-dimensional Mapping System for High-density Electro-anatomical Reconstruction
Published on: January 31, 2019
09:36Dual-Dye Optical Mapping of Hearts from RyR2R2474S Knock-In Mice of Catecholaminergic Polymorphic Ventricular Tachycardia
Published on: December 22, 2023
Related Concept Videos
Dysrhythmias II: Classification of Tachyarrhythmias
Dysrhythmias III: Characteristics of Dysrhythmias
Dysrhythmias IV: Characteristics of Bradyarrhythmias
Disturbances in Heart Rhythm
Arrhythmias are categorized by their speed, rhythm, and origin. A slow heart...
Mechanism of Cardiac Arrhythmias
Conduction System of the Heart
The pacemaker cells are located in two primary nodes: the sinoatrial (SA) node and the atrioventricular (AV) node. The SA node pacemaker cells can autonomously depolarize, triggering an action potential that leads to the...