Related Experiment Video
Updated: Apr 14, 2026

X-ray Dose Reduction through Adaptive Exposure in Fluoroscopic Imaging
Published on: September 11, 2011
[Report based on fiscal 2010 diagnostic X-ray equipment questionnaire survey (conditions of radiography)]
Yuya Koyano1, Toshinori Ide, Atsuko Tsukamoto
1Department of Radiology, NTT Medical Center Tokyo.
Abstract:
This is the eighth investigation which has been carried out every 5 years since 1974 for the purpose of grasping the trend of X-ray devices and the radiographic condition. We gathered it up mainly on a radiographic condition, in this report. As for the chest radiography and double contrast gastrography, introduction of the flat panel detector (FPD) advanced in comparison with the last survey. Ratio of the imaging system at chest radiography was 65% for computed radiography (CR), 33% for FPD, 1% for screen/film (S/F), and 1% for others. The radiographic condition of FPD was current time product less than CR. Ratio of the imaging system at gastrography was 3% for CR, 48% for FPD, 34% for image intensifier-digital radiography (I.I.-DR), and 15% for S/F. The tube voltage and the exposure time were similar to the last survey time, but the tube current became lower. Through this survey, the change of the radiographic condition was seen in the radiography part where introduction of the FPD advanced. We think the continuous survey is necessary in future.
Related Concept Videos
X-ray Imaging
Radiological Investigation I: X-ray and CT
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Radiological Investigation II: MRI and Ventilation Perfusion Scan
Magnetic Resonance Imaging (MRI) and Ventilation Perfusion Scans are two radiological investigations that offer detailed diagnostic images of the body, particularly lung structures.
MRI
MRI uses magnetic fields and radiofrequency signals to distinguish between normal and abnormal tissues. This technology provides a more detailed diagnostic image than CT scans, enabling it to characterize pulmonary nodules, stage bronchogenic carcinoma, and evaluate inflammatory activity in...
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...

