Related Experiment Video
Updated: Apr 14, 2026

Assessment of Dopaminergic Homeostasis in Mice by Use of High-performance Liquid Chromatography Analysis and Synaptosomal Dopamine Uptake
Published on: September 21, 2017
Spectrofluorimetric determination of dopamine receptor antagonist LE 300 in mice plasma
Mohamed Hefnawy1, Mostafa Mohamed1, Mohamed Abunassif1
1Pharmaceutical Chemistry Department, College of Pharmacy, King Saud University, P.O. Box 2457, Riyadh, 11451, Saudi Arabia.
Abstract:
A simple, rapid and highly sensitive spectrofluorimetric method was developed for determination of a novel type of dopamine receptor antagonist LE300 in mouse plasma. The method is based on measuring the native fluorescence of LE-300 in methanol at 343 nm after excitation at 280 nm. The fluorescence concentration plot was rectilinear over the range of 3.5-100 ng/mL with a lower detection limit of 1.0 ng/mL and quantification limit of 3.5 ng/mL. The method was statistically validated for linearity, accuracy, precision and selectivity according to the International Conference on Harmonization guidelines. The accuracy and precision results was expressed as % recovery and relative standard deviation (RSD). The accuracy for LE-300 was in the range 95.5-103.6% and RSD values were in the range of 0.21-1.55% of the theoretical value. The method was successfully applied to the analysis of LE-300 in mice plasma. The results were compared statistically with those obtained by the reported method and were found to be in good agreement, which could be applied in a pharmacokinetic study.