Improved Registration of 3D CT Angiography with X-ray Fluoroscopy for Image Fusion During Transcatheter Aortic Valve Implantation
Published on: June 3, 2018
CT evaluation prior to transapical aortic valve replacement: semi-automatic versus manual image segmentation
Borek Foldyna1, Camelia Jungert, Christian Luecke
1Department of Interventional and Diagnostic Radiology, University of Leipzig - Heart Center, Struempellstrasse 39, 04289, Leipzig, Germany, b.foldyna@gmail.com.
Abstract:
To compare the performance of semi-automatic versus manual segmentation for ECG-triggered cardiovascular computed tomography (CT) examinations prior to transcatheter aortic valve replacement (TAVR), with focus on the speed and precision of experienced versus inexperienced observers. The preoperative ECG-triggered CT data of 30 consecutive patients who were scheduled for TAVR were included. All datasets were separately evaluated by two radiologists with 1 and 5 years of experience (novice and expert, respectively) in cardiovascular CT using an evaluation software program with or without a semi-automatic TAVR workflow. The time expended for data loading and all segmentation steps required for the implantation planning were assessed. Inter-software as well as inter-observer reliability analysis was performed. The CT datasets were successfully evaluated, with mean duration between 520.4 ± 117.6 s and 693.2 ± 159.5 s. The three most time-consuming steps were the 3D volume rendering, the measurement of aorta diameter and the sizing of the aortic annulus. Using semi-automatic segmentation, a novice could evaluate CT data approximately 12.3% faster than with manual segmentation, and an expert could evaluate CT data approximately 10.3% faster [mean differences of 85.4 ± 83.8 s (p < 0.001) and 59.8 ± 101 s (p < 0.001), respectively]. The inter-software reliability for a novice was slightly lower than for an expert; however, the reliability for a novice and expert was excellent (ICC 0.92, 95% CI 0.75-0.97/ICC 0.96, 95% CI 0.91-0.98). Automatic aortic annulus detection failed in two patients (6.7%). The study revealed excellent inter-software and inter-observer reliability, with a mean ICC of 0.95. TAVR evaluation can be accomplished significantly faster with semi-automatic rather than with manual segmentation, with comparable exactness, showing a benefit for experienced and inexperienced observers.
More Related Videos
09:57Four-Dimensional Computed Tomography-Guided Valve Sizing for Transcatheter Pulmonary Valve Replacement
Published on: January 20, 2022
07:46Author Spotlight: Revolutionizing Remote Surgery with Augmented Reality and Robotics for Enhanced Precision and Accessibility
Published on: August 9, 2024