Retention of [(18)F]fluoride on reversed phase HPLC columns
Dieter Ory1, Jeroen Van den Brande1, Tjibbe de Groot2
1Laboratory for Radiopharmacy, Department of Pharmaceutical and Pharmacological Sciences KU Leuven, Leuven, Belgium.
Abstract:
As [(18)F]fluoride is a starting reagent in the radiosynthesis of most fluorine-18 labeled positron emission tomography (PET) tracers, its chromatographic behavior on reversed phase (RP) HPLC columns is important for the purification performance and accuracy of RP HPLC quality control methods. We have investigated the chromatographic behavior and recovery of [(18)F]fluoride as a function of the type and brand of RP HPLC column, the pH and the composition of the mobile phase. Elution and elution profile of [(18)F]fluoride from six RP-HPLC columns (Waters XBridge C18 3 mm × 100 mm 3.5 μm; Grace Platinum EPS C18 4.6 mm × 100 mm, 3 μm; Waters XTerra C18 4.6 mm × 250 mm, 5 μm; Phenomenex C18 4.6 mm × 150 mm, 5 μm; Hamilton PRP-1 column 4.1 mm × 150 mm, 5 μm; Merck KGaA Chromolith Performance C18 3 mm × 100 mm) eluted with mobile phase composed of phosphate or acetate buffers (pH 2, 3, 4, 5, 7.3 and 9) and acetonitrile or ethanol as organic modifier were characterized. The elution profile was determined by on-line radioactivity measurement in the column eluate and recovery was calculated by comparison of radioactivity eluted with the HPLC column present or absent in the chromatographic flow path. Interestingly, [(18)F]fluoride recovery increased with increasing pH. At pH 3 all packed silica-based columns showed significant retention of fluorine-18, whereas almost no retention was observed on a polymeric PRP-1 column. However at pH 5, [(18)F]fluoride recovery was above 90% for each tested column. In addition, small differences were observed when changing the composition of the mobile phase. We therefore recommend to use a mobile phase with pH > 5 for silica based C18 columns for both quality control and semi-preparative HPLC of fluorine-18 labeled PET radiopharmaceuticals. If required a lower pH can be used in combination with a polymer based HPLC column.
More Related Videos
12:55Quantification of Humic and Fulvic Acids in Humate Ores, DOC, Humified Materials and Humic Substance-Containing Commercial Products
Published on: March 18, 2022
13:36Simple In-House Ultra-High Performance Capillary Column Manufacturing with the FlashPack Approach
Published on: December 4, 2021
Related Concept Videos
Silica Gel Column Chromatography: Overview
Polar components tend to bind strongly to the silica gel, causing them to move slowly through the column. In contrast, nonpolar compounds...
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process:
Ion-Exchange Chromatography
High-Performance Liquid Chromatography: Elution Process
Ion Exchange
High-Performance Liquid Chromatography: Types of Detectors