Respiratory motion artefacts in dynamic liver MRI: a comparison using gadoxetate disodium and gadobutrol
Julian A Luetkens1, Patrick A Kupczyk1, Jonas Doerner1
1Department of Radiology, University of Bonn, Sigmund-Freud-Str. 25, 53127, Bonn, Germany.
Objectives:
Our aim was to retrospectively evaluate the occurrence of respiratory motion artefacts in patients undergoing dynamic liver magnetic resonance (MR) either with gadoxetate disodium or gadobutrol.
Methods:
Two hundred and thirty liver MR studies (115 with gadobutrol, 115 with gadoxetate disodium) were analysed. Respiratory motion artefacts on dynamic 3D T1-weighted MR images (pre-contrast, arterial, venous, and late-dynamic phase) were assessed using a five-point rating scale. Severe motion was defined as a score ≥ 4. Mean motion scores were compared with the Mann-Whitney-U-test. The chi-squared-test was used for dichotomous comparisons.
Results:
Mean motion scores for gadoxetate disodium and gadobutrol showed no relevant differences for each phase of the dynamic contrast series (pre-contrast: 1.85 ± 0.70 vs. 1.88 ± 0.57, arterial: 1.85 ± 0.81 vs. 1.87 ± 0.74, venous: 1.82 ± 0.67 vs. 1.74 ± 0.64, late-dynamic: 1.75 ± 0.62 vs. 1.79 ± 0.63; p = 0.469, 0.557, 0.382 and 0.843, respectively). Severe motion artefacts had a similar incidence using gadoxetate disodium and gadobutrol (11/460 [2.4%] vs. 7/460 [1.5%]; p = 0.341).
Conclusions:
Gadoxetate disodium is associated with equivalent motion scores compared to gadobutrol in dynamic liver MRI. In addition, both contrast agents demonstrated a comparable and acceptable rate of severe respiratory motion artefacts.
Key Points:
• Gadobutrol and gadoxetate disodium showed comparable motion scores in dynamic phase imaging. • The incidence of severe motion artefacts was pronounced in arterial phase imaging. • Adverse respiratory side effects were not recorded in 115 examinations with gadoxetate disodium.