Brief report: sound output of infant humidifiers
Allison K Royer1, Paul F Wilson2, Mark C Royer3
1Columbus Regional Health, Columbus, Indiana, USA aroyer@crh.org.
Insights
Some infant humidifiers produce high sound pressure levels (SPLs), potentially exceeding safe infant nursery limits. Further research is needed to assess hearing risks associated with these devices.
Area of Science:
- Environmental Health
- Pediatric Audiology
Background:
- Infant humidifiers are commonly used in nurseries.
- Assessing the acoustic environment for infants is crucial for development.
Purpose of the Study:
- To measure the sound pressure levels (SPLs) of common infant humidifiers.
- To determine potential sound exposure risks for infants and young children.
Main Methods:
- Five commercial infant humidifiers were tested.
- Sound levels were measured at 20, 100, and 150 cm at various settings.
- Measurements were taken in an audiology laboratory.
Main Results:
- Two of five (40%) humidifiers exceeded recommended infant nursery sound levels (50 dB) up to 100 cm.
- High decibel levels were observed in some infant-marketed humidifiers.
Conclusions:
- Infant humidifiers can generate significant sound pressure levels.
- Further studies are required to understand the impact of humidifier design on SPLs and associated hearing risks.
Abstract:
The sound pressure levels (SPLs) of common infant humidifiers were determined to identify the likely sound exposure to infants and young children. This primary investigative research study was completed at a tertiary-level academic medical center otolaryngology and audiology laboratory. Five commercially available humidifiers were obtained from brick-and-mortar infant supply stores. Sound levels were measured at 20-, 100-, and 150-cm distances at all available humidifier settings. Two of 5 (40%) humidifiers tested had SPL readings greater than the recommended hospital infant nursery levels (50 dB) at distances up to 100 cm. In this preliminary study, it was demonstrated that humidifiers marketed for infant nurseries may produce appreciably high decibel levels. Further characterization of the effect of humidifier design on SPLs and further elucidation of ambient sound levels associated with hearing risk are necessary before definitive conclusions and recommendations can be made.
More Related Videos
Related Concept Videos
Heart Sounds
Auscultation is the process of listening to these internal body sounds using a stethoscope. The heart produces four types of sounds, but only two—S1 and S2—can usually be heard with a stethoscope.
S1, also known as the "lub" sound, is caused by the closure of atrioventricular (A-V)...
Sound Intensity Level
The human ear can perceive an extensive range of sound intensity, necessitating the use of the logarithmic scale to define a physical quantity—the intensity level. It is a ratio of two intensities and...
Physical Assessment of the Respiratory Tract IV: Auscultation
Breath Sounds
Breath sounds are categorized into vesicular, bronchovesicular, and bronchial.
Intensity and Pressure of Sound Waves
Unlike the time average of a sinusoidal term, which is zero since it is positive...
Cardiovascular System Abnormal Findings II: Auscultation
Abnormal Heart Sounds
Gallops:
Sound Intensity