Study on detecting leachate leakage of municipal solid waste landfill site
Jiangang Liu1, Xianxian Cao2, Yingbo Ai2
1School of Earth Science and Engineering, Hohai University, Nanjing, China Liujg02@163.com.
Abstract:
The article studies the detection of the leakage passage of leachate in a waste landfill dam. The leachate of waste landfill has its own features, like high conductivity, high chroma and an increasing temperature, also, the horizontal flow velocity of groundwater on the leakage site increases. This article proposes a comprehensive tracing method to identify the leakage site of an impermeable membrane by using these features. This method has been applied to determine two leakage sites of the Yahu municipal solid waste landfill site in Pingshan District, Shenzhen, China, which shows that there are two leachate leakage passages in the waste landfill dam A between NZK-2 and NZK-3, and between NZK-6 and NZK-7.