High-resolution 3D-GRE imaging of the abdomen using controlled aliasing acceleration technique - a feasibility study
Mamdoh AlObaidy1, Miguel Ramalho2, Kiran K R Busireddy3
1Department of Radiology, University of North Carolina at Chapel Hill, CB 7510-2001 Old Clinic Bldg., Chapel Hill, NC, 27599-7510, USA. mamdoh.alobaidy@yahoo.com.
European Radiology
|April 29, 2015
Summary
High-resolution abdominal MRI using controlled aliasing acceleration technique (CAIPIRINHA-VIBE) is feasible, offering sharper images and better lesion detection than standard methods. This technique improves image quality post-contrast, reducing artifacts and scan time.
Area of Science:
- Magnetic Resonance Imaging (MRI)
- Medical Imaging Technology
- Radiology
Background:
- Standard 3D-gradient-recalled echo (GRE) T1-weighted imaging with conventional acceleration (GRAPPA-VIBE) is widely used for abdominal MRI.
- Assessing the feasibility and performance of advanced acceleration techniques is crucial for improving diagnostic accuracy and efficiency.
Purpose of the Study:
- To evaluate the feasibility of high-resolution 3D-GRE fat-suppressed T1-weighted MRI using CAIPIRINHA-VIBE.
- To compare image quality and lesion detection between CAIPIRINHA-VIBE and GRAPPA-VIBE.
Main Methods:
- Eighty-four patients underwent abdominal MRI at 1.5 T using both CAIPIRINHA-VIBE (0.76 mm resolution) and GRAPPA-VIBE (1.17 mm resolution).
- Two independent readers assessed image quality, artifacts, lesion conspicuity, and detection.
- Statistical analysis included Kappa statistic, Wilcoxon signed-rank test, and logistic regression.
Main Results:
- CAIPIRINHA-VIBE demonstrated significantly sharper images and improved lesion conspicuity pre- and post-contrast (p < 0.001).
- This technique reduced respiratory motion and residual aliasing artifacts but showed increased noise and inferior fat suppression.
- Post-contrast CAIPIRINHA-VIBE yielded superior image quality and a trend towards improved hepatic lesion detection.
Conclusions:
- High-resolution abdominal 3D-GRE fat-suppressed T1-weighted imaging with CAIPIRINHA-VIBE is clinically feasible.
- CAIPIRINHA-VIBE provides sharper images, better lesion conspicuity, and reduced artifacts compared to standard GRAPPA-VIBE.
- This advanced technique offers potential for improved diagnostic performance and reduced scan times, especially for patients with breath-holding difficulties.
Related Concept Videos
Imaging Studies III: Computed Tomography
776
DefinitionComputed Tomography (CT) of the genitourinary (GU) tract is a non-invasive imaging modality that utilizes X-rays and computer processing to generate detailed cross-sectional images of the urinary system, encompassing the kidneys, ureters, bladder, and adjacent structures such as the adrenal glands.PurposeCT scans of the GU tract serve several diagnostic and therapeutic purposes, including:Diagnosis of Urinary Tract Diseases: Detects kidney stones, tumors, cysts, and congenital...
776
Imaging Studies for Cardiovascular System V: CT
614
Cardiac computed tomography (CT) scanning is an advanced cardiac imaging technique that utilizes CT technology, with or without intravenous (IV) contrast, to produce accurate cross-sectional virtual slices of specific areas of the heart, coronary circulation, and major blood vessels such as the aorta, pulmonary veins, and arteries. The computer processes these slices to generate three-dimensional images. Multidetector CT (MDCT) is a rapid form of CT scanning that captures multiple slices...
614
Computed Tomography
9.6K
Tomography refers to imaging by sections. Computed tomography (CT) is a non-invasive imaging technique that uses computers to analyze several cross-sectional X-rays to reveal minute details about structures in the body.
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
9.6K