Related Experiment Video
Updated: Apr 14, 2026

Image Rendering Techniques in Postmortem Computed Tomography: Evaluation of Biological Health and Profile in Stranded Cetaceans
Published on: September 27, 2020
A comparison of material decomposition techniques for dual-energy CT colonography
Radin A Nasirudin1, Rie Tachibana2, Janne J Näppi2
1Department of Diagnostic and Interventional Radiology, Technische Universität München, Munich, Germany.
Abstract:
In recent years, dual-energy computed tomography (DECT) has been widely used in the clinical routine due to improved diagnostics capability from additional spectral information. One promising application for DECT is CT colonography (CTC) in combination with computer-aided diagnosis (CAD) for detection of lesions and polyps. While CAD has demonstrated in the past that it is able to detect small polyps, its performance is highly dependent on the quality of the input data. The presence of artifacts such as beam-hardening and noise in ultra-low-dose CTC may severely degrade detection performances of small polyps. In this work, we investigate and compare virtual monochromatic images, generated by image-based decomposition and projection-based decomposition, with respect to CAD performance. In the image-based method, reconstructed images are firstly decomposed into water and iodine before the virtual monochromatic images are calculated. On the contrary, in the projection-based method, the projection data are first decomposed before calculation of virtual monochromatic projection and reconstruction. Both material decomposition methods are evaluated with regards to the accuracy of iodine detection. Further, the performance of the virtual monochromatic images is qualitatively and quantitatively assessed. Preliminary results show that the projection-based method does not only have a more accurate detection of iodine, but also delivers virtual monochromatic images with reduced beam hardening artifacts in comparison with the image-based method. With regards to the CAD performance, the projection-based method yields an improved detection performance of polyps in comparison with that of the image-based method.
More Related Videos
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies III: Gastrointestinal Motility Studies and Virtual Colonoscopy
Radionuclide Testing
Radionuclide testing is a sophisticated medical technique for assessing gastrointestinal motility. It focuses on gastric emptying and colonic transit time. Radioactive markers track the movement of food through the digestive system, providing insights into gastrointestinal disorders.
In gastric emptying studies, a meal's liquid and...
Imaging Studies for Cardiovascular System V: CT
X-ray Imaging
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Radiological Investigation I: X-ray and CT

