Comparison of the repeatability of GABA-edited magnetic resonance spectroscopy with and without macromolecule
Mark Mikkelsen1, Krish D Singh1, Petroc Sumner1
1CUBRIC, School of Psychology, Cardiff University, Cardiff, United Kingdom.
Purpose:
The inhibitory neurotransmitter γ-aminobutyric acid (GABA) can be measured in vivo using edited magnetic resonance spectroscopy (MRS), but quantification suffers from contamination by macromolecules (MM). It is possible to suppress this contamination using symmetric editing, but this procedure potentially compromises reliability of the GABA measurement. The aim of this study was to compare the repeatability of GABA-edited MRS with and without MM suppression.
Methods:
GABA' (non-MM contaminated) and GABA'+MM (MM-contaminated) concentration was measured in the occipital lobe (OCC) and anterior cingulate (AC) using symmetric and standard editing (n = 15). Each method was performed twice in each region.
Results:
Within-participant coefficients of variation for each technique were 4.0% (GABA'+MM) and 8.6% (GABA') in the OCC and 14.8% (GABA'+MM) and 12.6% (GABA') in the AC. Intraclass correlation coefficients were better for the suppression method than standard editing in both the OCC (0.72 versus 0.67) and AC (0.41 versus 0.16). These findings were replicated in the OCC of a second cohort (n = 15).
Conclusion:
Symmetric suppression is shown to be comparable in repeatability to standard GABA-editing. Measuring a purer quantification of GABA becomes increasingly important as more research is conducted on links between GABA concentration, pathology and healthy behavior.
More Related Videos
09:01Metabolomic Analysis of Rat Brain by High Resolution Nuclear Magnetic Resonance Spectroscopy of Tissue Extracts
Published on: September 21, 2014
11:27Preparation and In Vitro Characterization of Dendrimer-based Contrast Agents for Magnetic Resonance Imaging
Published on: December 4, 2016
Related Concept Videos
NMR Spectrometers: Resolution and Error Correction
Chemical Shift: Internal References and Solvent Effects
The internal reference compound generally used in NMR spectroscopy is tetramethylsilane (TMS). TMS is preferred because it is chemically inert, soluble in NMR solvents, and easily removable. Also, the highly shielded methyl protons in TMS yield an intense...
¹³C NMR: ¹H–¹³C Decoupling
A broadband decoupling technique is used to simplify these complex, sometimes overlapping, signals. Broadband decoupling relies on a...
NMR Spectroscopy: Chemical Shift Overview
For instance, the proton...
¹H NMR: Interpreting Distorted and Overlapping Signals
As Δν decreases and the signals move closer, the doublets appear increasingly distorted. The intensities of the inner lines increase at the cost of those of the outer lines as the signals are...
Double Resonance Techniques: Overview
Spin decoupling is usually achieved by...