Related Experiment Video
Updated: Apr 13, 2026

In Vivo Quantitative Assessment of Myocardial Structure, Function, Perfusion and Viability Using Cardiac Micro-computed Tomography
Published on: February 16, 2016
Splenic Switch-off: A Tool to Assess Stress Adequacy in Adenosine Perfusion Cardiac MR Imaging
Charlotte Manisty1, David P Ripley1, Anna S Herrey1
1From the Heart Hospital Imaging Centre, University College London, 16-18 Westmoreland St, London W1G 8PH, England (C.M., A.S.H., G.C., J.C.M.); Multidisciplinary Cardiovascular Research Centre and Leeds Institute of Genetics, Health and Therapeutics, University of Leeds, Leeds, England (D.P.R., S.P., J.P.G.); Department of Medicine (T.C.W., E.B.S.) and UPMC Cardiovascular Magnetic Resonance Center (E.B.S.), University of Pittsburgh School of Medicine, Pittsburgh, Pa; NIHR Cardiovascular Biomedical Research Unit, Barts Health NHS Trust and Queen Mary University of London, London, England (S.E.P.); and Wessex Cardiothoracic Unit, Southampton University Hospitals NHS Trust, Southampton, England (C.P.).
Purpose:
To investigate the pharmacology and potential clinical utility of splenic switch-off to identify understress in adenosine perfusion cardiac magnetic resonance (MR) imaging.
Materials And Methods:
Splenic switch-off was assessed in perfusion cardiac MR examinations from 100 patients (mean age, 62 years [age range, 18-87 years]) by using three stress agents (adenosine, dobutamine, and regadenoson) in three different institutions, with appropriate ethical permissions. In addition, 100 negative adenosine images from the Clinical Evaluation of MR Imaging in Coronary Heart Disease (CE-MARC) trial (35 false and 65 true negative; mean age, 59 years [age range, 40-73 years]) were assessed to ascertain the clinical utility of the sign to detect likely pharmacologic understress. Differences in splenic perfusion were compared by using Wilcoxon signed rank or Wilcoxon rank sum tests, and true-negative and false-negative findings in CE-MARC groups were compared by using the Fisher exact test.
Results:
The spleen was visible in 99% (198 of 200) of examinations and interobserver agreement in the visual grading of splenic switch-off was excellent (κ = 0.92). Visually, splenic switch-off occurred in 90% of adenosine studies, but never in dobutamine or regadenoson studies. Semiquantitative assessments supported these observations: peak signal intensity was 78% less with adenosine than at rest (P < .001), but unchanged with regadenoson (4% reduction; P = .08). Calculated peak splenic divided by myocardial signal intensity (peak splenic/myocardial signal intensity) differed between stress agents (adenosine median, 0.34; dobutamine median, 1.34; regadenoson median, 1.13; P < .001). Failed splenic switch-off was significantly more common in CE-MARC patients with false-negative findings than with true-negative findings (34% vs 9%, P < .005).
Conclusion:
Failed splenic switch-off with adenosine is a new, simple observation that identifies understressed patients who are at risk for false-negative findings on perfusion MR images. These data suggest that almost 10% of all patients may be understressed, and that repeat examination of individuals with failed splenic switch-off may significantly improve test sensitivity.
More Related Videos
08:35Oxygenation-sensitive Cardiac MRI with Vasoactive Breathing Maneuvers for the Non-invasive Assessment of Coronary Microvascular Dysfunction
Published on: August 17, 2022
09:10Normothermic Ex Situ Heart Perfusion in Working Mode: Assessment of Cardiac Function and Metabolism
Published on: January 12, 2019
Related Concept Videos
Imaging Studies for Cardiovascular System IV: CMRI
Exercise Stress Test
Exercise stress testing, commonly known as a treadmill test, is a noninvasive procedure used to evaluate cardiovascular function and diagnose heart conditions.
Definition
An exercise stress test measures the heart's response to exertion using a treadmill or stationary bicycle. Chest electrodes record the heart's electrical activity through an ECG, and blood pressure is monitored regularly.
Purposes